Digital Electrocardiograms (digital + electrocardiogram)

Distribution by Scientific Domains


Selected Abstracts


Assessment of Noise in Digital Electrocardiograms

PACING AND CLINICAL ELECTROPHYSIOLOGY, Issue 4 2002
VELISLAV BATCHVAROV
BATCHVAROV, V., et al.: Assessment of Noise in Digital Electrocardiograms. Technically related noise in 12-lead ECGs recorded with ambulatory recorders has never been systematically compared with that in ECGs recorded with conventional ECGs. This study compared serial 10-second ECGs obtained in ten healthy men, age 22,45 years, who were recorded in the supine resting position using a (1) MAC VU recorder, (2) digital ambulatory SEER MC recorder with a Multi-Link detachable ECG cable, and (3) digital ambulatory SEER MC recorder with a light ambulatory ECG cable. In each ECG, averaged sinus rhythm cycles of the entire recording were realigned with the native signal and subtracted. The resulting "residuum" was quantified by computing its standard deviation and root mean square of successive differences (RMSSD). While the RMSSD residuum values were significantly lower with the MAC VU recorder (6.27 ± 0.98 ,V) than with the SEER MC recorder with either ECG cables (7.29 ± 1.31 and 7.17 ± 1.31 ,V, P < 0.003 and p < 0.02), the difference was practically negligible and there was no detectable difference in the standard deviation residuum values. The study concludes that valid ECG investigations of serial ECG testing may be conducted using the ambulatory SEER MC recorders providing the biological sources of ECG noise are controlled. The available technology for noise assessment suggests that studies involving advanced analysis of serial ECGs (e.g., of drug related changes), should incorporate objective characterisation of ECG quality. [source]


Cardiac Arrhythmias Triggered by Sudden and Dynamic Efforts

ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, Issue 2 2010
Emanuel C. Furtado M.D.
Background: Some arrhythmias are triggered only during exercise. The aim of this study is to describe the frequency and type of arrhythmia induced by a standardized protocol of sudden and dynamic exercise, which tends to reflect routine situations of efforts (e.g., climbing stairs), and compare with those found on maximal cardiopulmonary exercise test (CPET). Methods: A total of 2329 subjects (1594 men) aged 9,91 years (mean 52 years, SD ± 16) were submitted to a standardized protocol of sudden and dynamic exercise (4-second exercise test [4sET]) prior to a CPET. A continuous digital electrocardiogram (ECG) was recorded during 4sET and CPET, and later reviewed and interpreted by the same physician (who supervised all the procedures). Results: A total of 1125 subjects (43%) had cardiac arrhythmias during one or both procedures. About 57% of the arrhythmias were supraventricular, but 47 subjects (2% of all subjects) presented more complex arrhythmias including 43 cases of nonsustained supraventricular tachycardia and four nonsustained ventricular tachycardia. While arrhythmias were more often exposed by the CPET (P < 0.01), in 221 cases (10% of the total sample) of arrhythmias they were only induced by 4sET; these included four cases of nonsustained supraventricular tachycardia. Conclusion: 4sET-induced arrhythmias tend to be simple and were always short-lasting. In some cases, ECG recording during 4sET showed arrhythmias that would not be induced by a progressive maximal exercise test. Different situations of exercise, sudden and short versus maximal and progressive, tend to generate different arrhythmic responses and possibly complementary clinical implications. Ann Noninvasive Electrocardiol 2010;15(2):151,156 [source]


Differences in the morphology and duration between premature P waves and the preceding sinus complexes in patients with a history of paroxysmal atrial fibrillation

CLINICAL CARDIOLOGY, Issue 7 2003
Polychronis E. Dilaveris M.D.
Abstract Background: Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Experimental and human mapping studies have demonstrated that perpetuation of AF is due to the presence of multiple reentrant wavelets with various sizes in the right and left atria. Hypothesis: Atrial fibrillation may be induced by atrial ectopic beats originating in the pulmonary veins, and premature P-wave (PPW) patterns may help to identify the source of firing. Methods: To evaluate the morphology and duration of PPWs, 12-lead digital electrocardiogram (ECG) strips containing clearly definable PPWs not merging with the preceding T waves were obtained in 25 patients with AF history (9 men, mean age 59.5 ± 2.2 years) and 25 subjects without any previous AF history (11 men, mean age 53.6 ± 2.5 years). The polarity of PPWs was evaluated in all 12 ECG leads. Previously described indices, such as P maximum, P dispersion (= P maximum ,P minimum), P mean, and P standard deviation were also calculated. Results: Premature P-wave patterns were characterized by more positive P waves in lead V1. All P-wave analysis indices were significantly higher in patients with AF than in controls when calculated in the sinus beat, whereas they did not differ between the two groups when calculated in the PPW. P-wave indices did not differ between the PPW and the sinus P wave in either patients with AF or controls, except for P mean, which was significantly higher in the sinus (110.1 ± 1.7 ms) than in the PPW (100 ± 2 ms) only in patients with AF (p = 0.001). Conclusion: The evaluation of PPW patterns is only feasible in a small percentage of short-lasting digital 12-lead ECG recordings containing ectopic atrial beats. Premature P wave patterns are characterized by more positive P waves in lead V1, which indicates a left atrial origin in the ectopic foci. The observed differences in P-wave analysis indices between patients with AF and controls and between sinus beats and PPWs may be attributed to the presence of electrophysiologic changes in the atrial substrate. [source]