Diffraction Line Profiles (diffraction + line_profile)

Distribution by Scientific Domains


Selected Abstracts


Diffraction line profiles from polydisperse crystalline systems

ACTA CRYSTALLOGRAPHICA SECTION A, Issue 5 2001
Paolo Scardi
Diffraction patterns for polydisperse systems of crystalline grains of cubic materials were calculated considering some common grain shapes: sphere, cube, tetrahedron and octahedron. Analytical expressions for the Fourier transforms and corresponding column-length distributions were calculated for the various crystal shapes considering two representative examples of size-distribution functions: lognormal and Poisson. Results are illustrated by means of pattern simulations for a f.c.c. material. Line-broadening anisotropy owing to the different crystal shapes is discussed. The proposed approach is quite general and can be used for any given crystallite shape and different distribution functions; moreover, the Fourier transform formalism allows the introduction in the line-profile expression of other contributions to line broadening in a relatively easy and straightforward way. [source]


Effect of a crystallite size distribution on X-ray diffraction line profiles and whole-powder-pattern fitting

JOURNAL OF APPLIED CRYSTALLOGRAPHY, Issue 3-2 2000
J. I. Langford
A distribution of crystallite size reduces the width of a powder diffraction line profile, relative to that for a single crystallite, and lengthens its tails. It is shown that estimates of size from the integral breadth or Fourier methods differ from the arithmetic mean of the distribution by an amount which depends on its dispersion. It is also shown that the form of `size' line profiles for a unimodal distribution is generally not Lorentzian. A powder pattern can be simulated for a given distribution of sizes, if it is assumed that on average the crystallites have a regular shape, and this can then be compared with experimental data to give refined parameters defining the distribution. Unlike `traditional' methods of line-profile analysis, this entirely physical approach can be applied to powder patterns with severe overlap of reflections, as is demonstrated by using data for nanocrystalline ceria. The procedure is compared with alternative powder-pattern fitting methods, by using pseudo-Voigt and Pearson VII functions to model individual line profiles, and with transmission electron microscopy (TEM) data. [source]


An in situ method for the study of strain broadening using synchrotron X-ray diffraction

JOURNAL OF APPLIED CRYSTALLOGRAPHY, Issue 4 2007
C. C. Tang
A tensonometer for stretching metal foils has been constructed for the study of strain broadening in X-ray diffraction line profiles. This device, which is designed for use on powder diffractometers and was tested on Station 2.3 at Daresbury Laboratory, allows in situ measurements to be performed on samples under stress. It can be used for data collection in either transmission or reflection modes using either symmetric or asymmetric diffraction geometries. As a test case, measurements were carried out on an 18,µm-thick copper foil experiencing strain levels of up to 5% using both symmetric reflection and symmetric transmission diffraction. All the diffraction profiles displayed peak broadening and asymmetry which increased with strain. The measured profiles were analysed by the fundamental-parameters approach using the TOPAS peak-fitting software. All the observed broadened profiles were modelled by convoluting a refineable diffraction profile, representing the dislocation and crystallite size broadening, with a fixed instrumental profile predetermined using high-quality LaB6 reference powder. The deconvolution process yielded `pure' sample integral breadths and asymmetry results which displayed a strong dependence on applied strain and increased almost linearly with applied strain. Assuming crystallite size broadening in combination with dislocation broadening arising from f.c.c. a/2,110,{111} dislocations, the variation of mechanical property with strain has been extracted. The observation of both peak asymmetry and broadening has been interpreted as a manifestation of a cellular structure with cell walls and cell interiors possessing high and low dislocation densities. [source]


Effect of a crystallite size distribution on X-ray diffraction line profiles and whole-powder-pattern fitting

JOURNAL OF APPLIED CRYSTALLOGRAPHY, Issue 3-2 2000
J. I. Langford
A distribution of crystallite size reduces the width of a powder diffraction line profile, relative to that for a single crystallite, and lengthens its tails. It is shown that estimates of size from the integral breadth or Fourier methods differ from the arithmetic mean of the distribution by an amount which depends on its dispersion. It is also shown that the form of `size' line profiles for a unimodal distribution is generally not Lorentzian. A powder pattern can be simulated for a given distribution of sizes, if it is assumed that on average the crystallites have a regular shape, and this can then be compared with experimental data to give refined parameters defining the distribution. Unlike `traditional' methods of line-profile analysis, this entirely physical approach can be applied to powder patterns with severe overlap of reflections, as is demonstrated by using data for nanocrystalline ceria. The procedure is compared with alternative powder-pattern fitting methods, by using pseudo-Voigt and Pearson VII functions to model individual line profiles, and with transmission electron microscopy (TEM) data. [source]