Dermatitis Clinic (dermatitis + clinic)

Distribution by Scientific Domains

Kinds of Dermatitis Clinic

  • contact dermatitis clinic


  • Selected Abstracts


    Dermatitis caused by physical irritants

    BRITISH JOURNAL OF DERMATOLOGY, Issue 2 2002
    R. Morris-Jones
    SummaryBackground Although physical irritant contact dermatitis (PICD) is a common occupational dermatosis, it is one of the least well understood because of its multiple types, lack of diagnostic test, and the many mechanisms involved in its production. Objectives To characterize the materials and mechanisms of physical irritation of the skin. Methods We did a retrospective analysis over the past 20 years of all patients with a diagnosis of PICD at St John's Institute of Dermatology Contact Dermatitis Clinic. Results Of the 29 000 patients who attended the clinic over the study period, 392 patients were diagnosed with PICD and of these, 335 files were analysed. Conclusions Our findings show that PICD accounted for 1·15% of all patients attending the contact clinic over the study period. Diverse occupations and materials were implicated. The most common cause of PICD was low humidity due to air-conditioning, which caused dermatitis of the face and neck in office workers due to drying out of the skin. [source]


    European Standard Series patch test results from a contact dermatitis clinic in Israel during the 7-year period from 1998 to 2004

    CONTACT DERMATITIS, Issue 2 2006
    Aneta Lazarov
    The results of a 7-year retrospective study (1998,2004) from patch testing with the European Standard Series (ESS) establishing the frequency of sensitization in a contact dermatitis clinic in Israel are presented. 23 allergens were patch tested on 2156 patients, 1462 females (67.8%) and 694 males (32.2%). Atopy and asthma were present in 21.9% of the patients. One or more allergic reactions were observed in 937 patients (43.5%). The highest yield of patch test positives from the 1076 positive reactions were obtained from nickel sulfate (13.9%), fragrance mix (7.1%), potassium dichromate (3.8%), Balsam of Peru (3.6%), CL + Me-isothiazolinone (3.4%) and cobalt chloride (3.4%). Allergens which produced the least amount of positive results were primin and clioquinol. Allergic contact dermatitis (ACD) was established in 32.8%, whereas occupationally related allergic (8.0) and irritant contact dermatitis (5.6%) affected a total of 13.6% of the cases studied. The most common clinical forms of dermatitis were chronic dermatitis (47.7%) followed by acute dermatitis (22.8%), and lichenification and hyperkeratosis (7.9%). The hands (30.7%), face and neck (23.9%) and extremities (11.3%) were the most frequently affected areas. Four allergens in our study differed from the top 10 allergens in Europe namely: Cl + Me-isothiazolinone, formaldehyde, 4-tert-butylphenol formaldehyde resin and sesquiterpene lactone mix reflecting an existing difference in environmental exposure. Our study is the first to provide data on the frequency of sensitization and important allergens in the aetiology of ACD in Israel. In spite of the existing differences with Europe, we conclude that ESS is an appropriate screening system for the diagnosis of ACD in Israel. [source]


    Palladium allergy in an Israeli contact dermatitis clinic

    CONTACT DERMATITIS, Issue 4 2003
    Edith Orion
    No abstract is available for this article. [source]


    Simultaneous sensitivity to fragrances

    BRITISH JOURNAL OF DERMATOLOGY, Issue 5 2006
    D.A. Buckley
    Summary Background, Cinnamal/cinnamic alcohol and isoeugenol/eugenol are pairs of related fragrance chemicals found in Fragrance Mix I (FM I), and thus are routinely tested in combination with other fragrances in the European standard patch test series. Their close structural similarity makes the occurrence of simultaneous sensitivity within these chemical pairs likely, although at present there are no robust data to support this hypothesis. Objectives, To establish the frequency of simultaneous reactions to these fragrance chemicals in patients with suspected fragrance allergy attending a contact dermatitis clinic; to provide evidence in support of proposed metabolic pathways; and to determine whether including all four separately in FM I is necessary to avoid missing a diagnosis of fragrance allergy. Methods, We analysed retrospectively the records of patients patch tested to the European standard series during the 15-year period 1984,98 for positive reactions to FM I. In a subset of patients tested to the constituents of FM I, positive reactions to cinnamal, cinnamic alcohol, isoeugenol and eugenol were sought. Data were analysed using 2 × 2 contingency tables (Fisher's exact test). Results, During this period, 23 660 patients were tested to the European standard series, of whom 1811 (7·7%) had positive reactions to FM I. Of the 1112 patients tested to the constituents of FM I, 934 had positive reactions to at least one constituent (total 1324 positive reactions to constituents). Of these 934, 826 also had positive reactions to FM I itself; 108 were negative to FM I but reacted to one or more of its constituents. One hundred and seventy-eight patients did not react to any of the breakdown constituents of FM I; 34 of these had positive reactions to FM I itself. Of 139 patients allergic to cinnamic alcohol, 87 were also allergic to cinnamal (63%), compared with 108 (11·1%) of 973 cinnamic alcohol-negative patients (P < 0·00001). Of 231 patients allergic to isoeugenol, 50 were also allergic to eugenol (22%), vs. 109 (12·4%) of 881 isoeugenol-negative patients (P = 0·0002). Conclusions, These data support in vitro experiments indicating that cinnamal and cinnamic alcohol may generate a common hapten and are consistent with the view that simultaneous sensitization to isoeugenol and eugenol occurs to a limited extent, despite their being metabolized via different pathways. In view of the substantial number of isolated reactions to each of these fragrance chemicals, all four should continue to be included separately as constituents of FM I. [source]


    p -Phenylenediamine sensitization is more prevalent in central and southern European patch test centres than in Scandinavian: results from a multicentre study

    CONTACT DERMATITIS, Issue 6 2009
    Jacob Pontoppidan Thyssen
    Background:, Positive patch test reactions to p -phenylenediamine (PPD) are common. PPD is used in oxidative hair dyes and is also present in dark henna temporary ,tattoos'. Cross-sensitization to other contact allergens may occur. Because subjects sensitized to PPD are at risk of clinically severe reactions upon hair dyeing, there is a need for ,current' prevalence data on PPD sensitization. Objectives:, To compare PPD patch test results from dermatitis patients tested between 2003 and 2007 in 10 European patch test centres and to analyse the causes and determine relevance of positive PPD patch test reactions. Materials:, Patch testing was performed using PPD (1% free base in petrolatum from Trolab (Almirall Hermal GmbH, Reinbeck, Germany) or Chemotechnique (Malmö, Sweden), equivalent to 0.090 mg/cm2 in the TRUE® test from MEKOS Laboratories AS). Statistical analysis was performed using the chi-squared test. Results:, The weighted average prevalence was 4.6% among 21 515 patients. PPD sensitization occurred more often in centres located in Central and Southern Europe than in Scandinavian centres (odds ratio = 2.40; 95% confidence interval = 2.07,2.78). The overall proportion of positive patch test reactions to PPD that were registered as being of either current or ,past' relevance was high (weighted average 53.6% and 20.3%, respectively). Consumer hair dyeing was the most prominent cause of PPD sensitization (weighted average 41.8%). Furthermore, occupational hair dye exposure (10.6%) and cross-sensitization to textile dyes (12.6%) were frequently reported. Conclusions:, PPD sensitization caused by exposure to hair dyes is frequent and remains a present problem for patients visiting contact dermatitis clinics, especially in patch test centres located in Central and Southern Europe. [source]


    Contact allergy to isoeugenol and its derivatives: problems with allergen substitution

    CONTACT DERMATITIS, Issue 5-6 2004
    S. Tanaka
    A total of 2261 (808 male, 1453 female) consecutive patients attending contact dermatitis clinics were patch tested to isoeugenol and its derivatives listed in the EU Inventory of Fragrance Ingredients. Positive reactions were found to isoeugenol in 40, transisoeugenol in 40, isoeugenyl acetate in 19, isoeugenyl benzoate in 4, isoeugenyl phenylacetate in 16, isoeugenyl methyl ether in 6 and benzyl isoeugenyl ether in 2 patients. There was a concomitant reaction to isoeugenol in 36/40 of those positive to transisoeugenol, 13/19 of those to isoeugenyl acetate, 3/4 of those to isoeugenyl benzoate and 15/16 of those to isoeugenyl phenylacetate but in none of those 6 positive to isoeugenyl methyl ether and in neither of those 2 positive to benzyl isoeugenyl ether. Concomitant contact allergy between isoeugenol and its derivatives may occur through chemical cross-reactivity or local skin metabolism of the derivatives. It is more commonly observed with the esters rather than the ethers. Isoeugenyl acetate has been proposed as an alternative to isoeugenol, but there is a high degree of concomitant reactivity with isoeugenol. [source]