Days Post-operatively (day + post-operatively)

Distribution by Scientific Domains


Selected Abstracts


A composite poly-hydroxybutyrate,glial growth factor conduit for long nerve gap repairs

JOURNAL OF ANATOMY, Issue 6 2003
P.-N. Mohanna
Abstract There is considerable evidence that peripheral nerves have the potential to regenerate in an appropriate microenvironment. We have developed a novel artificial nerve guide composed of poly 3-hydroxybutyrate (PHB) filled with glial growth factor (GGF) suspended in alginate hydrogel. Gaps of 2,4 cm in rabbit common peroneal nerve were bridged using a PHB conduit containing either GGF in alginate hydrogel (GGF) or alginate alone (Alginate), or with an empty PHB conduit (Empty). Tissues were harvested 21, 42 and 63 days post-operatively. Schwann cell and axonal regeneration were assessed using quantitative immunohistochemistry. At 21 days, addition of GGF increased significantly the distance of axonal and Schwann cells regeneration in comparison with that observed in Alginate and Empty conduits for both gap lengths. The axons bridged the 2-cm GGF conduits gap by 63 days, with a comparable rate of regeneration seen in 4-cm conduits. Schwann cells and axonal regeneration quantity was similar for both gap lengths in each group. However, at all time points the quantity of axonal and Schwann cells regeneration in GGF grafts was significantly greater than in both Alginate and Empty conduits, the latter showing better regeneration than Alginate conduits. The results indicate an inhibitory effect of alginate on regeneration, which is partially reversed by the addition of GGF to the conduits. In conclusion, GGF stimulates a progressive and sustainable regeneration increase in long nerve gap conduits. [source]


Non-viral VEGF165 gene therapy , magnetofection of acoustically active magnetic lipospheres (,magnetobubbles') increases tissue survival in an oversized skin flap model

JOURNAL OF CELLULAR AND MOLECULAR MEDICINE, Issue 3 2010
Thomas Holzbach
Abstract Adenoviral transduction of the VEGF gene in an oversized skin flap increases flap survival and perfusion. In this study, we investigated the potential of magnetofection of magnetic lipospheres containing VEGF165 -cDNA on survival and perfusion of ischemic skin flaps and evaluated the method with respect to the significance of applied magnetic field and ultrasound. We prepared perfluoropropane-filled magnetic lipospheres (,magnetobubbles') from Tween60-coated magnetic nanoparticles, Metafectene, soybean-oil and cDNA and studied the effect in an oversized random-pattern-flap model in the rats (n= 46). VEGF-cDNA-magnetobubbles were administered under a magnetic field with simultaneously applied ultrasound, under magnetic field alone and with applied ultrasound alone. Therapy was conducted 7 days pre-operative. Flap survival and necrosis were measured 7 days post-operatively. Flap perfusion, VEGF-protein concentration in target and surrounding tissue, formation and appearance of new vessels were analysed additionally. Magnetofection with VEGF-cDNA-magnetobubbles presented an increased flap survival of 50% and increased flap perfusion (P < 0.05). Without ultrasound and without magnetic field, the effect is weakened. VEGF concentration in target tissue was elevated (P < 0.05), while underlying muscle was not affected. Our results demonstrate the successful VEGF gene therapy by means of magnetobubble magnetofection. Here, the method of magnetofection of magnetic lipospheres is equally efficient as adenoviral transduction, but has a presumable superior safety profile. [source]


Anaesthesia and post-operative morbidity after elective groin hernia repair: a nation-wide study

ACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 2 2008
M. BAY-NIELSEN
Background: Randomised studies suggest regional anaesthesia to have the highest morbidity and local infiltration anaesthesia to have the lowest morbidity after groin hernia repair. However, implications and results of this evidence for general practice are not known. Methods: Prospective nation-wide data collection in a cohort of n=29,033 elective groin hernia repairs, registered in the Danish Hernia Database in three periods, namely July 1998,June 1999, July 2000,June 2001 and July 2002,June 2003. Retrospective analysis of complications in discharge abstracts, identified from re-admission within 30 days post-operatively, prolonged length of stay (>2 days post-operatively) or death. Results: Complications after groin hernia repair were more frequent in patients 65+ years (4.5%), compared with younger patients (2.7%) (P<0.001). In patients 65+ years, medical complications were more frequent after regional anaesthesia (1.17%), compared with general anaesthesia (0.59%) (P=0.003) and urological complications were more frequent after regional anaesthesia (0.87%), compared with local infiltration anaesthesia (0.09%) (P=0.006). Seventeen prostatectomies occurred after post-operative urinary retention, but with no case after local anaesthesia. Mortality within 30 days after elective groin hernia repair was 0.12%. Regional anaesthesia was disproportionately more often used in patients dying within 1 week post-operatively. Conclusion: Choice of the anaesthetic technique should be adjusted to available procedure-specific scientific evidence and the use of regional anaesthesia in elderly patients undergoing groin hernia repair is not supported by existing evidence. [source]


Patterns in current anaesthesiological peri-operative practice for colonic resections: a survey in five northern-European countries

ACTA ANAESTHESIOLOGICA SCANDINAVICA, Issue 9 2006
P. Hannemann
Background:, For colorectal surgery, evidence suggests that optimal management includes: no pre-operative fasting, a thoracic epidural analgesia continued for 2 days post-operatively, and avoidance of fluid overload. In addition, no long-acting benzodiazepines on the day of surgery and use of short-acting anaesthetic medication may be beneficial. We examined whether these strategies have been adopted in five northern-European countries. Methods:, In 2003, a questionnaire concerning peri-operative anaesthetic routines in elective, open colonic cancer resection was sent to the chief anaesthesiologist in 258 digestive surgical centres in Scotland, the Netherlands, Denmark, Sweden and Norway. Results:, The response rate was 74% (n = 191). Although periods of pre-operative fasting up to 48 h were reported, most (> 85%) responders in all countries declared to adhere to guidelines for pre-operative fasting and oral clear liquids were permitted until 2,3 h before anaesthesia. Solid food was permitted up to 6,8 h prior to anaesthesia. In all countries more than 85% of the responders indicated that epidural anaesthesia was routinely used. Except for Denmark, long-acting benzodiazepines were still widely used. Short-acting anaesthetics were used in all countries except Scotland where isoflurane is the anaesthetic of choice. With the exception of Denmark, intravenous fluids were used unrestrictedly. Conclusion:, In northern Europe, most anaesthesiologists adhere to evidence-based optimal management strategies on pre-operative fasting, thoracic epidurals and short-acting anaesthetics. However, premedication with longer-acting agents is still common. Avoidance of fluid overload has not yet found its way into daily practice. This may leave patients undergoing elective colonic surgery at risk of oversedation and excessive fluid administration with potential adverse effects on surgical outcome. [source]


Long-term pericardial catheterization is associated with minimum foreign-body response

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, Issue 2 2007
Carlo R. Bartoli BS
Abstract Objectives: The goals of this study were to assess the feasibility and to characterize the foreign-body response of a long-term catheter in the pericardium. Background: Long-term access to the normal pericardial space provides opportunities for diagnostic sampling and therapeutic intervention. Methods: After thoracotomy, in 7 anesthetized canines, the pericardium was opened and a 5 French silicone vascular access catheter was advanced 10 cm into the pericardial sac toward the apex of the heart. A hydraulic coronary balloon occluder was implanted (N = 6). Pericardium was sealed with Prolene suture. Catheters were tunneled to the nape of the neck, attached to a subcutaneous vascular access port, and buried in the fascia. Animals underwent multiple experimental coronary artery occlusions across months. At sacrifice, we assessed the histopathological response of pericardium and epicardium to chronically indwelling silicone catheters. Results: Post-mortem examinations were performed at 213 days post-operatively (mean, range = 96,413, N = 6), with one animal maintained for longer-term study. At sacrifice, all catheters were bidirectionally patent and completely mobile in the pericardium without evidence of tissue overgrowth around the intrapericardial segment. Adhesion tissue was found only at the site of catheter entry through the pericardium. Microscopic histopathological examination at catheter entry site, surrounding pericardium, and myocardium revealed minimum chronic inflammation. Conclusions: This subcutaneous system provides dependable, chronic access to the normal pericardial space for drug delivery and sampling. The presence of a chronic silicone catheter in the pericardium does not precipitate clinically significant pathologic changes even after repeated ischemic events. © 2007 Wiley-Liss, Inc. [source]


Morphometric evaluation of the repair of critical-size defects using demineralized bovine bone and autogenous bone grafts in rat calvaria

CLINICAL ORAL IMPLANTS RESEARCH, Issue 8 2008
Rodrigo Cardoso de Oliveira
Abstract Objective: To evaluate the repair of critical-size bone defects in rats treated with demineralized bovine bone (DBB) compared with autogenous bone (AB). Material and method: A bone defect of 8 mm in diameter was created in the calvaria of 50 Rattus norvegicus, treated either with DBB or AB. Sub-groups of five rats of each group were killed at 7, 14, 21, 30 and 90 days post-operatively, and the skulls were removed and processed histologically. Histological sections were stained with hematoxylin and eosin. Result: Histological analysis showed complete closure of the defects with new bone at 90 days in group AB, and substitution of the biomaterial by fibrotic connective tissue in the DBB group at 21 days. Morphometric analysis showed that DBB was rapidly absorbed at 14 days, with its volume density decreasing from 47%±0.8% at 7 days to 1.2%±0.41% at 14 days. Subsequently, volume densities of the connective tissue and neoformed bone increased from 51.1%±11.17% to 86.8%±7.92% and from 1.9%±1.13% to 12%±8.02%, respectively, for the same time interval. The volume density of AB particles did not change throughout the experimental periods, but the amount of new bone increased markedly between 7 and 90 days, from 4.5%±1.57% to 53.5%±6.42% (P<0.05). Conclusion: DBB did not provide complete repair of the defects, with significantly less new bone formation than in the AB group. [source]