Home About us Contact | |||
Compression Force (compression + force)
Selected AbstractsHair breakage during combing.INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, Issue 6 2007Hair breakage during combing was evaluated by combing tresses and examining photographs of snags of hair fibers in combs. The resultant hair fiber arrangements suggest that breakage likely involves hair-on-hair interactions, and broken fragment size suggests that breakage occurs primarily at or near the hair-comb interface. Compression forces during combing were also measured, and impact loading of a hair fiber over another hair vs. a hair fiber over a comb tooth shows that compression and abrasion are important to breakage during combing and that impact loading of one hair fiber over another during snagging is a probable and important pathway for hair breakage. [source] Magnetic field exposure stiffens regenerating plant protoplast cell wallsBIOELECTROMAGNETICS, Issue 2 2006Toshihiko Haneda Abstract Single suspension-cultured plant cells (Catharanthus roseus) and their protoplasts were anchored to a glass plate and exposed to a magnetic field of 302,±,8 mT for several hours. Compression forces required to produce constant cell deformation were measured parallel to the magnetic field by means of a cantilever-type force sensor. Exposure of intact cells to the magnetic field did not result in any changes within experimental error, while exposure of regenerating protoplasts significantly increased the measured forces and stiffened regenerating protoplasts. The diameters of intact cells or regenerating protoplasts were not changed after exposure to the magnetic field. Measured forces for regenerating protoplasts with and without exposure to the magnetic field increased linearly with incubation time, with these forces being divided into components based on the elasticity of synthesized cell walls and cytoplasm. Cell wall synthesis was also measured using a cell wall-specific fluorescent dye, and no changes were noted after exposure to the magnetic field. Analysis suggested that exposure to the magnetic field roughly tripled the Young's modulus of the newly synthesized cell wall without any lag. Bioelectromagnetics 27:98,104, 2006. © 2005 Wiley-Liss, Inc. [source] Column restraint in post-tensioned self-centering moment framesEARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS, Issue 7 2010Chung-Che Chou Abstract Gaps between beam-to-column interfaces in a post-tensioned (PT) self-centering frame with more than one column are constrained by columns, which causes beam compression force different from the applied PT force. This study proposes an analytical method for evaluating column bending stiffness and beam compression force by modeling column deformation according to gap-openings at all stories. The predicted compression forces in the beams are validated by a cyclic analysis of a three-story PT frame and by cyclic tests of a full-scale, two-bay by first-story PT frame, which represents a substructure of the three-story PT frame. The proposed method shows that compared with the strand tensile force, the beam compression force is increased at the 1st story but is decreased at the 2nd and 3rd stories due to column deformation compatibility. The PT frame tests show that the proposed method reasonably predicts beam compression force and strand force and that the beam compression force is 2 and 60% larger than the strand force with respect to a minor restraint and a pin-supported boundary condition, respectively, at the tops of the columns. Therefore, the earlier method using a pin-supported boundary condition at upper story columns represents an upper bound of the effect and is shown to be overly conservative for cases where a structure responds primarily in its first mode. The proposed method allows for more accurate prediction of the column restraint effects for structures that respond in a pre-determined mode shape which is more typical of low and mid-rise structures. Copyright © 2009 John Wiley & Sons, Ltd. [source] THE EFFECT OF EXTRUDED FLOUR AND FERMENTATION TIME ON SOME QUALITY PARAMETERS OF IDLIJOURNAL OF FOOD QUALITY, Issue 1 2000KULWINDER KAUR ABSTRACT The effects on idli characteristics of fermentation time and substituting rice with differing proportions of rice flour extrusion-cooked under different conditions were studied. The specific gravity, pH and viscosity of batter and idli characteristics such as expansion, compression force and sensory attributes were measured and described using regression to fit a response surface analysis. Fermentation time showed the most pronounced effect on specific gravity, pH and aqueous dispersion viscosity of batter and taste scores of idli. Substituting rice flour with extruded rice flour at different levels were observed to have significant effect on expansion and appearance scores of idlis. The textural scores and compression force was significantly affected by extrusion temperature. The formulation containing rice substituted by 30% extruded rice flour extruded at 175C and fermented for 24 h produced idlis with highest expansion and overall acceptability. [source] Effect of cyclic mechanical loading on osteoclast recruitment in periodontal tissueJOURNAL OF PERIODONTAL RESEARCH, Issue 1 2010K. Nozaki Nozaki K, Kaku M, Yamashita Y, Yamauchi M, Miura H. Effect of cyclic mechanical loading on osteoclast recruitment in periodontal tissue. J Periodont Res 2009; doi: 10.1111/j.1600-0765.2008.01193.x. © 2009 The Authors. Journal compilation © 2009 Blackwell Munksgaard Background and Objective:, It is well accepted that cyclic mechanical loading induces osteoclastogenesis in periodontal tissue, but its molecular mechanisms are not well understood, in part because of a lack of appropriate models. In this study, we investigated a novel device that allows cyclic mechanical loading to be performed in a well-controlled manner. Furthermore, by employing this model, the effect of cyclic loading on osteoclast recruitment in the periodontal tissue was described. Material and Methods:, By using a newly developed device, the cyclic loading of 20 n (reference loading corresponding to the fracture hardness of dietary pellets) and two excessive loadings (i.e. 30 and 40 n) were applied to maxillary right molars in rats for up to 7 d, and osteoclast recruitment in the periodontal tissue was evaluated by analyzing relevant marker proteins using immunohistochemistry. Results:, Osteoclastogenesis was induced by day 3 within alveolar bone subjected to a compression force of 30 n. With both 30 and 40 n loadings, cells that were positive to for tartrate-resistant acid phosphate, receptor activator of nuclear factor-,B ligand and osteoprotegerin were significantly increased in the alveolar bone/periodontal ligament in a time-dependent manner. Conclusion:, A new device was developed that allows various levels of cyclic mechanical loading to be exerted. By using this device in rats, early events of osteoclast recruitment in the periodontal tissues were observed with excessive loadings in a time-dependent manner, indicating the usefulness of this model. [source] Quality by design, part I: Application of NIR spectroscopy to monitor tablet manufacturing processJOURNAL OF PHARMACEUTICAL SCIENCES, Issue 9 2008Simin Hassannejad Tabasi Abstract To monitor tableting production using near infrared (NIR) spectroscopy, chemometric models were developed to analyze peak compression force, crushing strength and content uniformity. To measure tablet content uniformity, orbifloxacin tablets with drug content ranging from 60 to 90 mg were made and analyzed using ultraviolet (UV) and NIR spectroscopy. To assess the compression force and crushing strength, several batches of tablets were made on a Stokes B2 rotary tablet press and compression force was varied from 360 to 3500 lb. Principal component analysis (PCA) was used to identify tablets with regular and capped tablets breakage patterns. Comparison of statistical parameters showed that partial least squares (PLS) models gave better fit than the multiple linear regression (MLR) models. The best fit PLS models had a standard error of calibration (SEC) and a standard error of prediction (SEP) for content uniformity of 1.13 and 1.36 mg; for compression force of 69.86 and 59.48 lb and for crushing strength 0.55 kP and 0.57 kP, respectively. NIR spectroscopy in combination with multivariate modeling is a rapid and nondestructive technique that could reliably predict content uniformity, compression force and crushing strength for orbifloxacin tablets. © 2008 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 97:4040,4051, 2008 [source] Failure Modes with Point Loading of Three Commercially Available Denture TeethJOURNAL OF PROSTHODONTICS, Issue 6 2008Andrew R. Moffitt DDS Abstract Purpose: A common problem associated with implant-supported prostheses is the fracture of denture teeth. This study was designed to compare the fracture modes of three denture teeth by compressive load at a 30° off-axis angle. Material and Methods: Three denture teeth (Vident Duostat, Ivoclar Vivadent, and Dentsply Trubyte) processed to two denture base processing systems [injection-molded (IM) SR-Ivocap system and compression-molded (CM) denture base resin] were evaluated. Each specimen was processed to a metal framework. Ultimate failure strength of each system when point loaded at a 30° off-axis angle was recorded, along with a visual inspection of each specimen. Results: The average load fracture for each group was (in N): Vident CM 1106.97 ± 223.20, Vident IM 1168.18 ± 322.52, Dentsply CM 1098.08 ± 286.32, Dentsply IM 1023.80 ± 282.45, Ivoclar CM 1616.98 ± 204.87, and Ivoclar IM 1373.54 ± 282.58. There was a significant difference between the groups and the Ivoclar CM group. The Ivoclar CM group had the highest average load force, and the Dentsply IM group had the lowest average load force. On average, the teeth within the groups fractured at a higher compression force than the average maximum occlusal force in natural dentition. Dentsply and Vident denture teeth fractured more horizontally, and the Ivoclar denture teeth fractured more vertically within the groups. There was no significant difference among the groups between the IM and CM processing methods. Conclusions: In the present in vitro study, all specimens were able to withstand 30° off-axis loading with the exception of one specimen. With these results, this would indicate that these denture teeth are able to withstand normal occlusal forces. [source] MEASUREMENT OF FIRMNESS OF FRESH-CUT SLICED TOMATO USING PUNCTURE TESTS , STUDIES ON SAMPLE SIZE, PROBE SIZE AND DIRECTION OF PUNCTUREJOURNAL OF TEXTURE STUDIES, Issue 5 2007MILZA M. LANA ABSTRACT In order to investigate the firmness of tomato slices, two experiments were performed. In the first one, Monte Carlo simulation was used to study the variation in firmness within and between slices. Adding more slices and more measurements per slice reduced the SD, but in general, the efficiency of adding more slices was higher. In the second experiment, the firmness of tomato slices was measured by puncture test during storage, using one of three flat-tipped cylindrical probes (3.5-, 2.5- and 1.5-mm diameter) in two directions, along or perpendicular to the main axis of the fruit. Changes in firmness were studied by nonlinear regression analysis. The same model could be applied to all combinations of probe size and direction with the same correction for shear and compression. It suggests that shear and compression forces decay with storage time according to the same mechanism, irrespective of the measurement direction. PRACTICAL APPLICATIONS Methodologies for both firmness evaluation and data analysis were presented. Monte Carlo simulation was used to optimize the number of samples for firmness assays. After calculating the experimental SD from preliminary experimental results, simulations were performed with different numbers of replicates and measurements per replicate, to find an optimal experimental design where the SD is minimized. Using nonlinear regression, the effects on firmness of probe size, puncture direction in relation to the plant tissue and storage time can be analyzed simultaneously. The incorporation of a correction factor to account for differences in firmness due to probe size was proposed. The relative influence of shear (s) and compression force (c) on the observed force is estimated. Results of interest for the industry were presented, confirming previous findings that the firmness of ripened tomato slices measured by puncture analysis does not change significantly during short-term storage at low temperature. [source] APPLICATION OF A COMPRESSION-RELAXATION TEST FOR THE CHARACTERIZATION OF BURLAT SWEET CHERRYJOURNAL OF TEXTURE STUDIES, Issue 1 2001PEDRO L. MARQUINA Mechanical parameters of Burlat sweet cherries (Prunus avium) were studied as a function of ripening during three consecutive years by using a penetration test, a compression test between two plates, and a compression-relaxation test. The latter yields the "apparent secant modulus," i. e. the ratio of the initial maximum compression force over the applied strain. This modulus is one of the most useful mechanical parameters to discriminate between batches because its value is clearly related to the variety and degree of ripeness. Thus, the compression-relaxation test consistently allowed the differentiation of cherries in five degrees of ripeness. [source] EVALUATION OF LENTIL TEXTURE MEASUREMENTS BY COMPRESSION TESTINGJOURNAL OF TEXTURE STUDIES, Issue 4 2000S. D. ARNTFIELD ABSTRACT The variability in texture for lentils of different size, from different locations and cooked for varying lengths of time was examined in relation to the sample size and the extent to which the sample was compressed during testing. The force to compress the lentils was found to be dependent on all variables examined and also demonstrated significant interactions between these variables. The coefficient of variability was dependent on the size of the lentil, a two-way interaction between sample size and compression and a three-way interaction between location, cooking time and sample size. Regardless of lentil size, location where the lentil was grown and the cooking time used, the variability in the texture readings was lowest when the larger sample size and maximum compression force were used. [source] Bone repair in mandibular body osteotomy after using 2.0 miniplate system , histological and histometric analysis in dogsINTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, Issue 2 2008Cássio Edvard Sverzut Summary The objective of this study was to evaluate the bone repair along a mandibular body osteotomy after using a 2.0 miniplate system. Nine adult mongrel dogs were subjected to unilateral continuous defect through an osteotomy between the mandibular 3rd and 4th premolars. Two four-hole miniplates were placed in accordance with the Arbeitgeimeinschaft für Osteosynthesefragen Manual. Miniplates adapted to the alveolar processes were fixed monocortically with 6.0-mm-length titanium alloy self-tapping screws, whereas miniplates placed near the mandible bases were fixed bicortically. At 2, 6 and 12 weeks, three dogs were sacrificed per period, and the osteotomy sites were removed, divided into three thirds (Tension Third, TT; Intermediary Third, IT; Compression Third, CT) and prepared for conventional and polarized light microscopy. At 6 weeks, while the CT repaired faster and showed bone union by woven bone formation, the TT and IT exhibited a ligament-like fibrous connective tissue inserted in, and connecting, newly formed woven bone overlying the parent lamellar bone edges. At 12 weeks, bone repair took place at all thirds. Histometrically, proportions of newly formed bone did not alter at TT, IT and CT, whereas significantly enhanced bone formation was observed for the 12-week group, irrespective of the third. The results demonstrated that although the method used to stabilize the mandibular osteotomy allowed bone repair to occur, differences in the dynamics of bone healing may take place along the osteotomy site, depending on the action of tension and compression forces generated by masticatory muscles. [source] Knee pain in the ACL-deficient osteoarthritic knee and its relationship to quality of lifePHYSIOTHERAPY RESEARCH INTERNATIONAL, Issue 2 2003Michael Hartwick Abstract Background and Purpose Pain during activities of daily living is a common presenting complaint of individuals with knee osteoarthritis and anterior cruciate ligament injury. Knee pain is also associated with a decrease in quality of life for people with osteoarthritis. The purpose of the present study was to examine the dose,response relationship between knee joint forces and painful symptoms, and whether the acute symptoms, were associated with individuals' quality of life. Method This was a cross-sectional cohort correlation study. Seventeen individuals with anterior cruciate ligament (ACL)-deficient knees diagnosed with ipsilateral knee osteoarthritis completed the ACL quality of life questionnaire (ACL-QOL). The subjects also rated pain associated with each of five incremental isometric knee extension tests, proportional to their body weight. Analysis of variance was used to assess the association between pain and normalized torque. Linear regression was used to assess the correlation between the ACL-QOL score and the total pain experienced during the graded test. Results A strong relationship was found between the level of perceived knee pain and the amount of isometric torque produced (Pearson's r = 0.98; p<0.001). There was a statistically significant relationship between pain during the graded isometric test and the ACL-QOL (Pearson's r = ,0.56; p = 0.016). Conclusions Since knee joint compression is a function of active isometric knee extension torque, increased painful symptoms were associated with increased compression forces at the knee joint for these subjects. The relationship between pain provocation and disease-specific quality of life provides evidence for the proposed joint provocation test for this subject population. Weakness caused by osteoarthritis (OA) may, in part, be a negative conditioning response that would need to be overcome in rehabilitation. Copyright © 2003 Whurr Publishers Ltd. [source] |