Acceptable Standards (acceptable + standards)

Distribution by Scientific Domains


Selected Abstracts


Effectiveness of screening and monitoring tests for diabetic retinopathy , a systematic review

DIABETIC MEDICINE, Issue 7 2000
A. Hutchinson
SUMMARY Aims To determine which screening and monitoring tests for diabetic retinopathy are most effective and under what circumstances. Methods A systematic review of the English language literature, published from 1983 to April 1999. Results Available studies are generally limited in their ability to answer the important questions on the effectiveness of tests for early detection of diabetic retinopathy. No randomized controlled trials were identified although primary studies exist for two screening tests: ophthalmoscopy, either direct or indirect, and retinal photography, using either mydriasis or non-mydriasis. Retinal photography under mydriasis appears to be the most effective test, with the majority reporting levels of sensitivity in excess of 80%. However effectiveness is compromised when photographs are ungradable. Ophthalmoscopy can also reach acceptable standards of sensitivity and specificity. Conclusion Based on an assessment of available cohort studies, the most effective strategy for testing is the use of mydriatic retinal photography with the additional use of ophthalmoscopy for cases where photographs are ungradable. This does not exclude the use of ophthalmoscopy alone for opportunistic case finding but there is evidence of considerable variation in effectiveness of this test. [source]


Global factors shaping the future of food aid: the implications for WFP

DISASTERS, Issue 2007
Daniel Maxwell
Food aid is a key component of a humanitarian response but its use in other programming contexts is subject to numerous criticisms. Even in humanitarian emergencies food aid is often late, unreliable and out of proportion to other elements of the response. Three major factors will shape the future of food aid. First, mechanisms of food aid governance are being reviewed and may undergo major changes,particularly the Food Aid Convention now that hopes have diminished for an Agreement on Agriculture at the World Trade Organisation. The second significant factor is donor agency trends. Overall levels of food aid have dropped fairly steadily in recent decades and there are several discernible trends in resource allocation, procurement and the use of food aid. The third factor is an emerging body of best practice that will define acceptable standards of food aid programming in the future. [source]


Setting school-level outcome standards

MEDICAL EDUCATION, Issue 2 2006
David T Stern
Background, To establish international standards for medical schools, an appropriate panel of experts must decide on performance standards. A pilot test of such standards was set in the context of a multidimensional (multiple-choice question examination, objective structured clinical examination, faculty observation) examination at 8 leading schools in China. Methods, A group of 16 medical education leaders from a broad array of countries met over a 3-day period. These individuals considered competency domains, examination items, and the percentage of students who could fall below a cut-off score if the school was still to be considered as meeting competencies. This 2-step process started with a discussion of the borderline school and the relative difficulty of a borderline school in achieving acceptable standards in a given competency domain. Committee members then estimated the percentage of students falling below the standard that is tolerable at a borderline school and were allowed to revise their ratings after viewing pilot data. Results, Tolerable failure rates ranged from 10% to 26% across competency domains and examination types. As with other standard-setting exercises, standard deviations from initial to final estimates of the tolerable failure rates fell, but the cut-off scores did not change significantly. Final, but not initial cut-off scores were correlated with student failure rates (r = 0.59, P = 0.03). Discussion, This paper describes a method to set school-level outcome standards at an international level based on prior established standard-setting methods. Further refinement of this process and validation using other examinations in other countries will be needed to achieve accurate international standards. [source]


Interlaboratory Comparison of Epstein-Barr Virus Viral Load Assays

AMERICAN JOURNAL OF TRANSPLANTATION, Issue 2 2009
J. K. Preiksaitis
To assess interlaboratory variability in qualitative and quantitative Epstein-Barr virus (EBV) viral load (VL) testing, we distributed a panel of samples to 28 laboratories in the USA, Canada and Europe who performed testing using commercially available reagents (n = 12) or laboratory-developed assays (n = 18). The panel included two negatives, seven constructed samples using Namalwa and Molt-3 cell lines diluted in plasma (1.30,5.30 log10 copies/mL) and three clinical plasma samples. Significant interlaboratory variation was observed for both actual (range 1.30,4.30 log10 copies/mL) and self-reported (range, 1.70,3.30 log10 copies/mL) lower limits of detection. The variation observed in reported results on individual samples ranged from 2.28 log10 (minimum) to 4.14 log10 (maximum). Variation was independent of dynamic range and use of commercial versus laboratory-developed assays. Overall, only 47.0% of all results fell within acceptable standards of variation: defined as the expected result ± 0.50 log10. Interlaboratory variability on replicate samples was significantly greater than intralaboratory variability (p < 0.0001). Kinetics of change in VL appears more relevant than absolute values and clinicians should understand the uncertainty associated with absolute VL values at their institutions. The creation of an international reference standard for EBV VL assay calibration would be an initial important step in quality improvement of this laboratory tool. [source]