Acute Stent Thrombosis (acute + stent_thrombosis)

Distribution by Scientific Domains


Selected Abstracts


Acute Stent Thrombosis in the Setting of Cocaine Abuse Following Percutaneous Coronary Intervention

JOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 1 2009
JOHN N. MAKARYUS M.D.
The treatment of acute coronary syndrome (ACS) in patients with documented cocaine abuse has always presented significant challenges. Issues related to medication compliance, the potential risks of beta adrenergic blockade, and possible continued cocaine abuse postmyocardial infarction necessitate a unique, individualized approach to these patients. Recent data in the era of extensive percutaneous coronary interventions (PCI) and intracoronary stent (ICS) implantation have raised questions regarding the safety of ICS in patients who may revert to cocaine abuse postacute coronary syndrome as a result of the potentially higher risk of stent thrombosis in these patients. While the precise reason as to why cocaine use may increase the risk of stent thrombosis is not fully understood, it is likely the result of a confluence of factors, including coronary vessel vasoconstriction, impaired vascular compliance, as well as the platelet-activating effect of cocaine. We present the case a 46-year-old male with a history of cocaine abuse who presented with an acute stent thrombosis 2 days post-PCI likely as a result of cocaine abuse on the day of discharge following initial stent implantation for a non-ST-elevation myocardial infarction (NSTEMI). We also review the literature regarding the safety of PCI in cocaine abusers. [source]


Two-Year Clinical Registry Follow-up of Endothelial Progenitor Cell Capture Stent Versus Sirolimus-Eluting Bioabsorbable Polymer-Coated Stent Versus Bare Metal Stents in Patients Undergoing Primary Percutaneous Coronary Intervention for ST Elevation Myocardial Infarction

JOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 2 2010
ERIC CHONG M.B.B.S., F.A.M.S., M.R.C.P.
Background: Endothelial progenitor cell (EPC) capture stent is designed to promote rapid endothelization and healing and is potentially useful in patients undergoing primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). We studied the intermediate-term efficacy and safety of EPC stent and compared that with sirolimus-eluting bioabsorbable polymer stent (CURA) and bare metal stent (BMS) in AMI patients. Methodology: Patients presenting with AMI who underwent primary PCI with the respective stents between January 2004 and June 2006 were enrolled in the single-center clinical registry. The study end-points were major adverse cardiac events (MACE) and stent thrombosis. Results: A total of 366 patients (EPC = 95, CURA = 53, BMS 218) were enrolled. Baseline demographics including age, gender, diabetes, renal impairment, predischarge left ventricular ejection fraction, and creatinine kinase level were comparable among the groups. Procedural success rate was 99.5%. Post-procedural thrombolysis in myocardial infarction (TIMI) 3 flow was achieved in EPC 91.6%, CURA 96.2%, and BMS 88.5% (P = 0.209). At 2 years, the MACE rate was EPC 13.7%, CURA 15.1%, and BMS 19.7% (P = 0.383). Target vessel revascularizations (TVR) were EPC 4.2%, CURA 9.4%, and BMS 6.0% (P = 0.439). Nonfatal myocardial infarctions were EPC 1.1%, CURA 3.8%, and BMS 4.1% (P = 0.364). One patient in the EPC group had acute stent thrombosis. There was no late stent thrombosis in the EPC group. Conclusion: EPC stent appeared to be safe and had comparable clinical efficacy with a BMS when used in the AMI setting. At 2-year follow-up, the EPC group showed favorable, single-digit TVR rate and stent thrombosis remained a low-event occurrence. (J Interven Cardiol 2010;23:101-108) [source]


Acute Stent Thrombosis in the Setting of Cocaine Abuse Following Percutaneous Coronary Intervention

JOURNAL OF INTERVENTIONAL CARDIOLOGY, Issue 1 2009
JOHN N. MAKARYUS M.D.
The treatment of acute coronary syndrome (ACS) in patients with documented cocaine abuse has always presented significant challenges. Issues related to medication compliance, the potential risks of beta adrenergic blockade, and possible continued cocaine abuse postmyocardial infarction necessitate a unique, individualized approach to these patients. Recent data in the era of extensive percutaneous coronary interventions (PCI) and intracoronary stent (ICS) implantation have raised questions regarding the safety of ICS in patients who may revert to cocaine abuse postacute coronary syndrome as a result of the potentially higher risk of stent thrombosis in these patients. While the precise reason as to why cocaine use may increase the risk of stent thrombosis is not fully understood, it is likely the result of a confluence of factors, including coronary vessel vasoconstriction, impaired vascular compliance, as well as the platelet-activating effect of cocaine. We present the case a 46-year-old male with a history of cocaine abuse who presented with an acute stent thrombosis 2 days post-PCI likely as a result of cocaine abuse on the day of discharge following initial stent implantation for a non-ST-elevation myocardial infarction (NSTEMI). We also review the literature regarding the safety of PCI in cocaine abusers. [source]


Contemporary use of embolic protection devices in saphenous vein graft interventions: Insights from the stenting of saphenous vein grafts trial,

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, Issue 2 2010
Neeraj Badhey MD
Abstract Background: We sought to evaluate the contemporary use of embolic protection devices (EPDs) in saphenous vein graft (SVG) interventions. Methods: We examined EPD use in the stenting of saphenous vein grafts (SOS) trial, in which 80 patients with 112 lesions in 88 SVGs were randomized to a bare metal stent (39 patients, 43 grafts, and 55 lesions) or paclitaxel-eluting stent (41 patients, 45 grafts, and 57 lesions). Results: An EPD was used in 60 of 112 lesions (54%). A Filterwire (Boston Scientific) was used in 70% of EPD-treated lesions, Spider (ev3, Plymouth, Minnesota) in 12%, Proxis (St. Jude, Minneapolis, Minnesota) in 12%, and Guardwire (Medtronic, Santa Rosa, California) in 7%. Of the remaining 52 lesions, an EPD was not utilized in 13 lesions (25%) because the lesion was near the distal anastomosis, in 14 lesions (27%) because of an ostial location, in one lesion (2%) because of small SVG size, in two in-stent restenosis lesions (4%) because of low distal embolization risk, and in 22 lesions (42%) because of operator's preference even though use of an EPD was feasible. Procedural success was achieved in 77 patients (96%); in one patient a Filterwire was entrapped requiring emergency coronary bypass graft surgery and two patients had acute stent thrombosis. Conclusion: In spite of their proven efficacy, EPDs were utilized in approximately half of SVG interventions in the SOS trial. Availability of a proximal protection device could allow protection of ,25% of unprotected lesions, yet operator discretion appears to be the major determinant of EPD use. © 2010 Wiley-Liss, Inc. [source]


A case report of simultaneous thrombosis of two coronary artery stents in association with clopidogrel resistance

CLINICAL CARDIOLOGY, Issue 4 2007
Jin Sun Lee B.S.
Abstract Despite aggressive antiplatelet therapy in the setting of PCI, the incidence of acute stent thrombosis remains approximately 0.5,2%. We report a patient with simultaneous thrombosis of two drug-eluting coronary artery stents, suggesting a systemic thrombotic state. Evaluation by optical platelet aggregometry revealed clopidogrel resistance, which was overcome at a higher drug dose. We aim to highlight the potential utility of platelet function analysis to guide therapy for patients in whom inadequate antiplatelet therapy may have catastrophic clinical outcomes. Copyright © 2007 Wiley Periodicals, Inc. [source]