Catheter Occlusion (catheter + occlusion)

Distribution by Scientific Domains


Selected Abstracts


The economics and practicality of t-PA vs tunnel catheter replacement for hemodialysis

HEMODIALYSIS INTERNATIONAL, Issue 1 2005
Cairoli O. Kaiser Permanente
Introduction:,Thrombolytic therapy is an important treatment modality for thrombosis-related catheter occlusion. Central venous access devices (CAVDs) are essential tools for the administration of many therapeutic modalities, especially for patients requiring lifetime therapy like hemodialysis. There are several reasons to salvage the occluded catheter. Catheter replacement results in an interruption of therapy delivery. This interruption may result in complications such as life-threatening metabolic and physiologic states. In addition, the patient's future access sites for CAVDs may be affected. The data released in the 2001 Annual Report , ESRD Clinical Performance Measures Project (Department of Health and Human Services, December 2001) shows 17% of prevalent patients were dialyzed with a chronic catheter continuously for 90 days or longer. In the pediatric population the data shows that 31% were dialyzed with a chronic catheter. The most common reasons for catheter placement included: no fistula or graft created (42%) and fistula and graft were maturing, not ready to cannulate (17%). Five percent of patients were not candidates for fistula or graft placement as all sites had been exhausted. Methods:,A short study was done in our medical center to evaluate the results of t-PA vs. changing the tunnel catheter. On an average a catheter costs about $400.00. If you add the cost of specialty personnel such as an interventional radiologist, radiology technician, radiology nurse, and the ancillaries such as the room, sutures, gauze, and tape, the total could reach $2000.00 easily. CathfloÔ Activase® costs around $60.00 for a single dose. T-PA was reconstituted by pharmacy personnel in single vials containing 2 mg/2 ml. Now with Cathflo, vials are stored in the renal clinic's refrigerator and when the need arises, the RN reconstitutes the medication. The RN, using established protocols, will instill Cathflo in the catheter following the volume requirements of the various tunnel catheters. After the t-PA is placed, the patient is sent home with instructions to return to their dialysis center the next day (arrangements are made by the RN as needed). In seventeen patients (17) with tunnel catheter malfunctions due to inadequate flow, not related to placement, t-PA was used. Of those 17 patients 2 were unable to use their catheter on their next dialysis treatment date, yielding an 88% success rate. This compares with clinical trials in which there is an 83% success rate with a dwell time of 4 hours, or an 89% rate on patients having a 2 hour dwell time (t-PA was repeated a second time if flow was not successfully restored. Results:,15/17 patients in our retrospective study showed that Cathflo worked successfully in restoring blood flow. Two catheters needed to be exchanged. The cost savings were significant when we compared the average cost of an exchange ($2000) versus using t-PA ($170 including nursing time). Conclusion:,Cathflo is not just safe and practical to use but also cost effective. [source]


Prospective investigation of a subcutaneous, implantable central venous access device for therapeutic plasma exchange in adults with neurological disorders

JOURNAL OF CLINICAL APHERESIS, Issue 1 2002
Basilio Pertiné
Abstract Standard alternatives to antecubital access for long-term therapeutic plasma exchange, including percutaneous polyurethane or tunneled silicone catheters, are associated with complications and inconvenience for the patient. We have investigated the Bard CathLink® 20, a subcutaneously implantable central venous access device, as an alternative for outpatient plasma exchange. The CathLink® 20 consists of a funnel-shaped titanium port connected to a soft polyurethane-derived catheter and is accessed percutaneously using an 18-gauge catheter-over-needle Angiocath®. Six patients with paraproteinemic polyneuropathies underwent 64 outpatient plasma exchanges using the CathLink® 20 for access, 31 using 2 CathLink® 20's (draw and return), 20 using a single CathLink® 20 as the draw site and 13 using a single CathLink® 20 as the return site. Mean (± SD) plasma removed was 3,680 ± 551 ml in 115.2 ± 25.3 min. Apheresis personnel were able to access the ports in 1.23 ± 0.6 attempts per port per procedure. Six of 70 planned procedures were aborted: 3 because of failure of an antecubital access site and 3 because of catheter occlusion resolved using a thrombolytic agent. Whole blood flow rate was approximately 54 ml/min, and plasma flow rate was about 32 ml/min for 135 min. Access pressures were stable at ,150 to ,200 torr (P = 0.1395). Return line pressures varied between 90 and 130 torr (P = 0.0147). No patient required hospitalization during the study. Though not optimized for apheresis, the CathLink® 20 provides a reasonable option for chronic apheresis patients who lack adequate peripheral venous access. J. Clin. Apheresis 17:1,6, 2002. © 2002 Wiley-Liss, 2002. [source]


Detection of peripherally inserted central catheter occlusion by in-line pressure monitoring

PEDIATRIC ANESTHESIA, Issue 7 2002
Junichi Arai MD
SummaryBackground: Peripherally inserted central catheters (PICC) are being increasingly used in neonatal practice. Their use is not without technical difficulty. This report describes the use of continuous pressure monitoring to detect catheter occlusion in critically ill neonates. Methods: In-line venous pressure of the PICC line was monitored by pressure transducer in neonates; 28-gauge 20 cm PICC or 29-gauge 25 cm PICC were used. Results: In-line pressure of the PICC was monitored 64 times in 50 neonates. Increases in the in-line pressure were observed when the catheter tip was against the vessel wall and the catheter was obstructed partially or completely. Decreases were observed when the infusion syringe was changed and when an inappropriate infusion rate was set. Two infants experienced marked variations of blood pressure due to intermittent catheter occlusion of the tip against the vessel wall. These infants were receiving dopamine via a PICC line. Conclusions: In critically ill infants, in-line pressure monitoring of the PICC is helpful in detecting the occlusion of the catheter. [source]


Central venous catheter occlusion during mitral valve replacement surgery

ANAESTHESIA, Issue 1 2009
S. Shah
No abstract is available for this article. [source]