Capillary Wall (capillary + wall)

Distribution by Scientific Domains


Selected Abstracts


CE coupled to MALDI with novel covalently coated capillaries

ELECTROPHORESIS, Issue 4 2010
Stefan Bachmann
Abstract CE offers the advantage of flexibility and method development options. It excels in the area of separation of ions, chiral, polar and biological compounds (especially proteins and peptides). Masking the active sites on the inner surface of a bare fused silica capillary wall is often necessary for CE separations of basic compounds, proteins and peptides. The use of capillary surface coating is one of the approaches to prevent the adsorption phenomena and improve the repeatability of migration times and peak areas of these analytes. In this study, new capillary coatings consisting of (i) derivatized polystyrene nanoparticles and (ii) derivatized fullerenes were investigated for the analysis of peptides and protein digest by CE. The coated capillaries showed excellent run-to-run and batch-to-batch reproducibility (RSD of migration time ,0.5% for run-to-run and ,9.5% for batch-to-batch experiments). Furthermore, the capillaries offer high stability from pH 2.0 to 10.0. The actual potential of the coated capillaries was tested by combining CE with MALDI-MS for analysing complex samples, such as peptides, whereas the overall performance of the CE-MALDI-MS system was investigated by analysing a five-protein digest mixture. Subsequently, the peak list (peptide mass fingerprint) generated from the mass spectra of each fraction was entered into the Swiss-Prot database in order to search for matching tryptic fragments using the MASCOT software. The sequence coverage of analysed proteins was between 36 and 68%. The established technology benefits from the synergism of high separation efficiency and the structure selective identification via MS. [source]


Use of coated capillaries for the electrophoretic separation of stereoisomers of a growth hormone secretagogue

ELECTROPHORESIS, Issue 21 2009
Reine Nehmé
Abstract The diastereoisomeric separation of peptidomimetics of hexarelin, a strong growth hormone secretagogue, in CE has been studied. Highly sulfated-,-CD was found to be an appropriate selector for the separation of the stereoisomers. However, non-repeatable analyses were obtained on bare fused silica capillary due to the progressive adsorption of the analytes on the capillary wall. Two types of polyelectrolyte coating agents were tested to prevent this phenomenon. Coating with neutral polyethylene oxide was found to be efficient but resulted in a very long analysis time (about 40,min). Coating with cationic poly(diallyldimethylammonium) chloride was found both to prevent analyte adsorption, reduce analysis time and alter separation selectivity. EOF measurement revealed that the highly sulfated-,-CDs were strongly adsorbed on the poly(diallyldimethylammonium) chloride coating surface yielding a stable strong cathodic EOF, which considerably reduced analysis time (about 12,min). Very good repeatability of analysis was obtained (RSDmigration time<1%). [source]


Co-electroosmotic capillary electrophoresis of basic proteins with 1-alkyl-3-methylimidazolium tetrafluoroborate ionic liquids as non-covalent coating agents of the fused-silica capillary and additives of the electrolyte solution

ELECTROPHORESIS, Issue 11 2009
Danilo Corradini
Abstract The paper reports the results of a study carried out to evaluate the use of three 1-alkyl-3-methylimidazolium-based ionic liquids as non-covalent coating agents for bare fused-silica capillaries and additives of the electrolyte solutions (BGE) for CE of basic proteins in the co-EOF separation mode. The three ionic liquids are differentiated from each other by the length of the alkyl group on the imidazolium cation, consisting of either an ethyl, butyl or octyl substituent, whereas tetrafluoroborate is the common anionic component of the ionic liquids. Coating the capillary with the ionic liquid resulted in improved peak shape and protein separation, while the EOF was maintained cathodic. This indicates that each ionic liquid is effective at masking the protein interaction sites on the inner surface of the capillary, also when its adsorption onto the capillary wall has not completely neutralized all the negative charges arising from the ionization of the silanol groups and the ionic liquid is not incorporated into the BGE employed for separation. Using the coated capillaries with BGE containing the ionic liquid employed for the coating, at concentration low enough to maintaining the EOF cathodic, both peak shape and protein separation varied to different extents, based on the particular ionic liquid used and its concentration. Fast and efficient separation of the model basic protein mixture in co-electroosmotic CE is obtained with the 1-butyl-3-methylimidazolium tetrafluoroborate coated capillary and 100,mM acetate buffer (pH 4.0) containing 4.4,mM 1-butyl-3-methylimidazolium tetrafluoroborate as the BGE. [source]


Sensitive analysis of donepezil in plasma by capillary electrophoresis combining on-column field-amplified sample stacking and its application in Alzheimer's disease,

ELECTROPHORESIS, Issue 17 2008
Hsin-Hua Yeh
Abstract Field-amplified sample stacking (FASS) in capillary electrophoresis (CE) was used to determine the concentration of donepezil, an acetylcholinesterase inhibitor, in human plasma. A sample pretreatment by liquid,liquid extraction with isopropanol/n -hexane (v/v 3:97) and subsequent quantification by FASS-CE was used. Before sample loading, a water plug (0.5,psi, 6,s) was injected to permit FASS. Electrokinetic injection (7,kV, 90,s) was used to introduce sample cations. The separation condition for donepezil was performed in electrolyte solutions containing Tris buffer (60,mM, pH 4.0) with sodium octanesulfonate 40,mM and 0.01% polyvinyl alcohol as a dynamic coating to reduce analytes' interaction with capillary wall. The separation was performed at 28,kV and detected at 200,nm. Using atenolol as an internal standard, the linear ranges of the method for the determination of donepezil in human plasma were over a range of 1,50,ng/mL. The limit of detection was 0.1,ng/mL (S/N=3, sampling 90,s at 7,kV). One female volunteer (54 years old) was orally administered a single dose of 10,mg donepezil (Aricept®, Eisai), and blood samples were drawn over a 60,h period for pharmacokinetic study. The method was also applied successfully to monitor donepezil in sixteen Alzheimer's disease patients' plasmas. [source]


Compositional effects on electrophoretic and chromatographic figures of merit in electrokinetic chromatography with cetyltrimethylammonium bromide/sodium octyl sulfate vesicles as the pseudostationary phase.

ELECTROPHORESIS, Issue 5 2008
Part 1: Effect of the phase ratio
Abstract The effect of the phase ratio on the electrophoretic and chromatographic properties of unilamellar vesicles comprised of cetyltrimethylammonium bromide (CTAB) and sodium octyl sulfate (SOS) was investigated in EKC. The surfactant concentration of the vesicles was 0.9, 1.2, 1.5, and 1.8% w/v, with a mole ratio of 1:3.66 (CTAB/SOS). Results were compared to those obtained using SDS micelles at concentrations of 1.0% (w/v, 35,mM) and 1.5% (52,mM). The CTAB/SOS vesicles (0.9,1.8% w/v) provided a significantly larger elution range (5.7,,,tves/t0,,,8.7) and greater hydrophobic (methylene) selectivity (2.8,,,,CH2,,,3.1) than SDS micelles (3.1,,,tmc/t0,,,3.3; ,CH2,=,2.2). Whereas the larger elution range can be attributed to the 25% reduction in EOF due to the interaction of unaggregated CTAB cations and the negatively charged capillary wall, the higher methylene selectivity is likely due to the lower concentration of water expected in the CTAB/SOS vesicle bilayer compared to the Palisades layer of SDS micelles. For a given phase ratio, CTAB/SOS vesicles are somewhat less retentive than SDS micelles, although retention factors comparable to those observed in 1.0,1.5% SDS can be obtained with 1.5,1.8% CTAB/SOS. A linear relationship was observed between phase ratio and retention factor, confirming the validity of the phase ratio model for these vesicles. Unique polar group selectivities and positional isomer shape selectivities were obtained with CTAB/SOS vesicles, with both types of selectivities being nearly independent of the phase ratio. For four sets of positional isomers, the elution order was always para < ortho < meta. Finally, the thermodynamics of solute retention was qualitatively similar to that reported for other surfactant aggregates (micelles and microemulsions); the enthalpic contribution to retention was consistently favorable for all compounds, whereas the entropic contribution was favorable only to hydrophobic solutes. [source]


Light-emitting diode-compatible probes for indirect detection of anions in CE

ELECTROPHORESIS, Issue 19 2007
Peter Balding
Abstract A range of compounds were evaluated as probes for the indirect detection of inorganic ions using CE and light-emitting diodes (LEDs) as the light source. Emphasis was placed on examining probes likely to absorb strongly in the UV,Vis region near 350,430,nm as compounds, which absorb at longer wavelengths tend to be bulkier and adsorb onto the capillary wall. These probes should act as a replacement for the very effective but carcinogenic probe chromate. Two probes were identified and evaluated: p -nitrophenol and 4-hydroxy-3,5-dinitrobenzoic acid. The former showed the most potential with low-mobility anions, while the later had a moderate electrophoretic mobility and was more suitable for a wider mobility range of analytes. However, neither could match the efficiencies and LOD of chromate for the separation of the fast inorganic ions such as chloride, nitrate and sulphate. Nevertheless, application of the 4-hydroxy-3,5-dinitrobenzoic acid system to the determination of oxalate in Bayer liquors showed excellent sensitivity and selectivity. [source]


Use of poly(vinyl alcohol)-coated capillaries for separation of amino-terminated polyamidoamine dendrimers

ELECTROPHORESIS, Issue 3 2007
Britton Carter
Abstract Characterization of amino-terminated polyamidoamine dendrimers by CE suffers from a lack of resolution for higher generations and poor between-day reproducibility of retention times. Under optimal conditions of temperature, voltage, and sample amount, 0,5,generations of dendrimers could be resolved with a bare fused-silica capillary. However, reproducibility was poor due to potential interactions of the polycationic dendrimers with the uncoated quartz capillary wall. Use of a poly(vinyl alcohol)-coated capillary significantly decreased the migration times of the nanomolecules without compromising resolution. Dendrimer mixtures containing generations,0,5 are separated as discrete, nonoverlapping peaks in about 15,min. In addition, the between-day precision of retention times was dramatically improved without the need for internal standards or data normalization. Dendrimers of various generations and cores run on different days showed an RSD of retention times of less than 4%. The poly(vinyl alcohol) coating was very stable as shown by the excellent precision of migration times obtained on a capillary used for a month with more than 100,injections. Similar to PAGE, separation of polyamidoamine dendrimers on a bare fused-silica and poly(vinyl alcohol)-coated capillary showed an exponential relationship between migration times and calculated charge density of the nanomolecules. [source]


Separation of cationic polymer particles and characterization of avidin-immobilized particles by capillary electrophoresis

ELECTROPHORESIS, Issue 5-6 2006
Yukihiro Okamoto
Abstract Cationic polymer microparticles have received much attention especially in the field of biotechnology, such that their analysis and separation have become important. So far, the separation of cationic polymer particles with different size using CE has not been achieved and the cationic particles migrated as if they are negatively charged, probably due to electrostatic interaction between capillary wall and cationic polymer particles. In this paper, the separation of cationic polymer microparticles by CE was investigated in detail. The separation of cationic particles with different size was achieved in CE by taking into account the interaction between sample particles and the inner surface of capillaries. By employing a poly(vinyl alcohol)-coated capillary, a better size separation of amine-modified latex particles was obtained compared to a Polybrene-coated capillary. It was elucidated that the composition, concentration, and pH of the background solution were also important factors in the separation of colloidal particles to avoid the surface adsorption and the characteristic aggregation of polymer particles. Furthermore, the CE analysis was applied to the characterization of cationic protein-immobilized particles. [source]


Capillary electrophoresis using copolymers of different composition as physical coatings: A comparative study

ELECTROPHORESIS, Issue 5-6 2006
Guillaume L. Erny
Abstract In this work, a comparative study on the use of different polymers as physically adsorbed coatings for CE is presented. It is demonstrated that the use of ad hoc synthesized polymers as coatings allows tailoring the EOF in CE increasing the flexibility of this analytical technique. Namely, different polymers were synthesized at our laboratory using different percentages of ethylpyrrolidine methacrylate (EpyM) and N,N -dimethylacrylamide (DMA). Thus, by modifying the percentage of EpyM and DMA monomers it is possible to manipulate the positive charge of the copolymer, varying the global electrical charge on the capillary wall and with that the EOF. These coated capillaries are obtained by simply flushing a given EpyM,DMA aqueous solution into bare silica capillaries. It is shown that by using these coated capillaries at adequate pHs, faster or more resolved CE separations can be achieved depending on the requirements of each analysis. Moreover, it is demonstrated that these coated capillaries reduce the electrostatic adsorption of basic proteins onto the capillary wall. Furthermore, EpyM,DMA coatings allow the reproducible chiral separation of enantiomers through the partial filling technique (PFT). The EpyM,DMA coated capillaries are demonstrated to provide reproducible EOF values independently of the pH and polymer composition with%RSD values lower than 2% for the same day. It is also demonstrated that the coating procedure is reproducible between capillaries. The compatibility of this coating protocol with CE in microchips is discussed. [source]


Capillary electrophoresis of polycationic poly(amidoamine) dendrimers

ELECTROPHORESIS, Issue 15 2005
Xiangyang Shi
Abstract Generation,2 to generation,5 poly(amidoamine) (PAMAM) dendrimers having different terminal functionalities were analyzed by capillary electrophoresis (CE). Polyacrylamide gel electrophoresis was also used to assess the composition of the individual generations for comparison with the CE results. Separation of PAMAMs can be accomplished by either using uncoated silica or silanized silica capillaries, although reproducibility is poor using the uncoated silica capillary. To improve run-to-run reproducibility, silanized capillary was used and various internal standards were also tested. Relative and normalized migration times of primary amine terminated PAMAM dendrimers were then determined using 2,3-diaminopyridine (2,3-DAP) as an internal standard. Using silanized capillaries and internal standards, the relative and normalized migration times are fully reproducible and comparable between runs. Apparent dimensionless electrophoretic mobilities were determined and the results were compared to theoretical calculations. It is concluded that for PAMAMs a complex separation mechanism has to be considered in CE, where the movement of the ions is due to the electric field, but the separation is rather the consequence of the adsorption/desorption equilibria on the capillary wall ("electrokinetic capillary chromatography"). The described method may be used for quality control and may serve as an effective technique to analyze polycationic PAMAM dendrimers and their derivatives with different surface modifications. [source]


Rapid separation of protein isoforms by capillary zone electrophoresis with new dynamic coatings

ELECTROPHORESIS, Issue 11 2005
William W. P. Chang
Abstract Many cellular functions are regulated through protein isoforms. Changes in the expression level or regulatory dysfunctions of isoforms often lead to developmental or pathological disorders. Isoforms are traditionally analyzed using techniques such as gel- or capillary-based isoelectric focusing. However, with proper electroosmotic flow (EOF) control, isoforms with small pI differences can also be analyzed using capillary zone electrophoresis (CZE). Here we demonstrate the ability to quickly resolve isoforms of three model proteins (bovine serum albumin, transferrin, ,1 -antitrypsin) in capillaries coated with novel dynamic coatings. The coatings allow reproducible EOF modulation in the cathodal direction to a level of 10 -9 m2V -1s -1. They also appear to inhibit protein adsorption to the capillary wall, making the isoform separations highly reproducible both in peak areas and apparent mobility. Isoforms of transferrin and ,1 -antitrypsin have been implicated in several human diseases. By coupling the CZE isoform separation with standard affinity capture assays, it may be possible to develop a cost-effective analytical platform for clinical diagnostics. [source]


Application of dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium in wall modification for capillary electrophoresis separation of proteins

ELECTROPHORESIS, Issue 3 2005
Wei Wei
Abstract A zwitterionic surfactant, dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium (C12H25N+(CH3)2CH2CHOHCH2SO3,), named dodecyl sulfobetaine (DSB), was used as a novel modifier to coat dynamically capillary walls for capillary electrophoresis separation of basic proteins. The DSB coating suppressed the electroosmotic flow (EOF) in the pH range of 3,12. At high DSB concentration, the EOF was suppressed by more than 8.8,times. The DSB coating also prevented successfully the adsorption of cationic proteins on the capillary wall. Anions, such as Cl,, Br,, I,, SO42,, CO32,, and ClO4,, could be used as running buffer modifiers to adjust the EOF for better separation of analytes. Using this dynamically coated capillary, a mixture of eight inorganic anions achieved complete separation within 4.2,min with the efficiencies from 24,000 to 1,310,000,plates/m. In the presence of ClO4, as EOF adjustor, the separation of a mixture containing four basic proteins (lysozyme, cytochrome c, ,-chymotrypsinogen,A, and myoglobin) yielded efficiencies of 204,000,896,000,plates/m and recoveries of 88%,98%. Migration time reproducibility of these proteins was less than 0.5% relative standard deviation (RSD) from run to run and less than 3.1% RSD from day to day, showing promising application of this novel modifier in protein separation. [source]


Nanowires for surface enlargement of narrow-bore fused-silica tubing

ELECTROPHORESIS, Issue 21-22 2004
Andreas Woldegiorgis
Abstract A method for preparation of silica nanowires with dimensions of d = 10,100 nm, l = 5,500 nm, is described. The nanostructured material is an integral part of the inner surface of narrow bore fused-silica capillary tubing. The wire preparation method is based on a decomposition of 2-chloro-1,1,2-trifluoroethyl methyl ether at elevated temperature and pressure. The silica bulk material is rearranged via a sustained silica-hydrogen fluoride chemistry, and reaction mechanisms for this process are proposed. The method is suitable for preparing long lengths of tubing with the modified surface. It is our belief that the texture of the capillary wall with its increased surface area is useful for applications such as microreactions, catalysis, and high-resolution pressure and/or electrodriven open-tubular liquid chromatography. [source]


Gemcitabine-induced severe pulmonary toxicity

FUNDAMENTAL & CLINICAL PHARMACOLOGY, Issue 1 2004
Fabrice Barlési
Abstract Gemcitabine is a relatively new deoxycytidine analog (2,,2,-difluorodeoxycytidine) with structural similarities to cytosine arabinoside (Ara-C). Activity of gemcitabine is demonstrated in the treatment of many solid tumors, like pancreas, ovarian and nonsmall cell lung cancer (NSCLC). Although gemcitabine is considered as a drug with a good safety profile, cases of gemcitabine-induced severe pulmonary toxicity (GISPT) were reported as for Ara-C. We performed a systematic review of reported cases on the GISPT. Twenty-nine clinical trials especially interesting NSCLC patients (21) and 21 reported cases recording 40 patients were analyzed. The incidence of the GISPT varies from 0 to 5%. The clinical presentation is a subacute clinical syndrome and is frequently nonspecific. The predominant radiographic pattern on chest X-ray are reticulo-nodular interstitial infiltrates. It was postulated that the physio-pathological mechanism of the GISPT was an inflammatory reaction of the alveolar capillary wall cytokine-mediated, which created an abnormal permeability of its membrane. After the differential diagnosis were ruled out, the discontinuation of the drug and the early initiation of steroids and diuretics are the most frequently performed treatments. Under these conditions, the outcome was favorable in a delay of few days generally for a majority of patients but 20% of patients died. Some risk factors, as a previous pulmonary disease or a previous thoracic irradiation, for the occurrence of the GISPT were proposed. GISPT is rare but sometimes fatal. Its a necessity to increase awareness about it to enhanced an early and suitable management of patients developing such a toxicity after gemcitabine administration. [source]


Ex vivo organ culture of adipose tissue for in situ mobilization of adipose-derived stem cells and defining the stem cell niche

JOURNAL OF CELLULAR PHYSIOLOGY, Issue 3 2010
Young-Il Yang
In spite of the advances in the knowledge of adipose-derived stem cells (ASCs), in situ location of ASCs and the niche component of adipose tissue (AT) remain controversial due to the lack of an appropriate culture system. Here we describe a fibrin matrix-supported three-dimensional (3D) organ culture system for AT which sustains the ASC niche and allows for in situ mobilization and expansion of ASCs in vitro. AT fragments were completely encapsulated within the fibrin matrix and cultured under dynamic condition. The use of organ culture of AT resulted in a robust outgrowth and proliferation in the fibrin matrix. The outgrown cells were successfully recovered from fibrin by urokinase treatment. These outgrown cells fulfilled the criteria of mesenchymal stem cells, adherence to plastic, multilineage differentiation, and cell surface molecule expression. In vitro label retaining assay revealed that newly divided cells during the culture resided in interstitium between adipocytes and capillary endothelial cells. These interstitial stromal cells proliferated and outgrew into the fibrin matrix. Both in situ mobilized and outgrown cells expressed CD146 and ,-smooth muscle actin (SMA), but no endothelial cell markers (CD31 and CD34). The structural integrity and spatial approximation of CD31,/CD34,/CD146+/SMA+ interstitial stromal cells, adipocytes, and capillary endothelial cells were well preserved during in vitro culture. Our results suggest that ASCs are natively associated with the capillary wall and more specifically, belong to a subset of pericytes. Furthermore, organ culture of AT within a fibrin matrix-supported 3D environment can recapitulate the ASC niche in vitro. J. Cell. Physiol. 224: 807,816, 2010. © 2010 Wiley-Liss, Inc. [source]


Modeling of protein breakthrough performance in cryogel columns by taking into account the overall axial dispersion

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 15-16 2009
Junxian Yun
Abstract A model considering the overall axial dispersion for describing protein adsorption and breakthrough in monolithic cryogel beds has been developed. The microstructure of cryogels was characterized by tortuous capillaries with a normal diameter distribution but a constant pore wall thickness. The axial dispersion within cryogel columns was described by using the overall axial dispersion coefficient, which can be easily obtained by matching the experimental breakthrough curves without adsorption or measuring residence time distributions (RTDs). Experimental breakthrough curves of lysozyme within a metal-chelated affinity cryogel by Persson et al. (Biotechnol. Bioeng. 2004, 88, 224,236) and a cation-exchange cryogel by Yao et al. (J. Chromatogr. A 2007, 1157, 246,251) were employed as examples to test the model. The results showed that by using the axial dispersion coefficient and assuming uniform radial concentration profile at a given cross-section of the cryogel along the bed height, the model can describe the detailed behaviors of the in-bed overall axial dispersion, the in-pore mass transfer, as well as the protein adsorption and breakthrough. For a known overall axial dispersion coefficient, the lumped parameter of the mass transfer coefficient between the bulk liquid and the capillary wall can be determined by fitting the protein breakthrough curve at a known chromatographic condition. Once this parameter is determined, the model can be used to predict the protein breakthrough profiles under different conditions based on the basic physical parameters of the cryogel bed and the properties of the fluid and protein. The effective capillary diameters employed in the model are close to the actual pore sizes observed from the images by SEM. The model predictions of lysozyme breakthrough profiles at various flow rates are also in good agreement with the experimental data in both the metal-chelated affinity and cation-exchange cryogel columns. [source]


Investigation of the separability of thaumatin by capillary electrophoresis

JOURNAL OF SEPARATION SCIENCE, JSS, Issue 8 2003
Milena Vespalcová
Abstract The electrophoretic behaviour of the highly basic protein thaumatin was explored in strongly acid (pH 2) and mildly acid (pH 4.5) separation systems using both bare and coated fused silica capillaries. The separation selectivity for thaumatin I, thaumatin II, and for other sample constituents was insufficient for their baseline separation at pH 2 in an uncoated capillary because the separation efficiency was markedly lower than is common in the electrophoretic separations of proteins. A separation selectivity higher by up to one order of magnitude has been reached at pH 4.5. A pronounced asymmetry of zones, which impaired resolution at this pH, was effectively suppressed by coating of the capillary wall with a polymer. In fact, adsorption on the capillary coating always plays a contributory role whenever a good separation of thaumatin constituents is attained. This indicates that electrochromatographic separation systems based on capillaries coated with the layer of either cationic or hydrophilic uncharged polymer hold promise for the development of methods for thaumatin analysis. [source]


Microvascular Solute and Water Transport

MICROCIRCULATION, Issue 1 2005
FITZ-ROY E. CURRY
ABSTRACT Objective: This review evaluate [1] the regulation of water and solute transport across the endothelial barrier in terms of pore theory and the glycocalyx-junction-break model of capillary permeability; and [2] the mechanisms regulating permeability based on experiments using cultured endothelial cells and intact microvessels. Conclusions: The current form of the glycocalyx-junction-break model of capillary permeability describes the selectivity of the capillary wall (pore size) in terms of the space between the fibers of a quasi-periodic matrix on the endothelial cell surface and the area for exchange (pore number) in terms of the length and frequency of breaks in the tight junction strands. An independent test of this model in a range of mammalian microvascular beds is new experimental evidence that the colloid osmotic pressure of plasma proteins is developed across the glycocalyx, not across the whole microvessel wall. We are beginning to understand that endothelial cells may change their phenotype in response to physical and chemical stresses. Such changes in phenotype may explain changes in the regulation of endothelial barrier function in intact microvessels that have previously been exposed to injury and differences in the regulation of contractile mechanisms between endothelial cells in vivo and in vitro. [source]


Application of dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium in wall modification for capillary electrophoresis separation of proteins

ELECTROPHORESIS, Issue 3 2005
Wei Wei
Abstract A zwitterionic surfactant, dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium (C12H25N+(CH3)2CH2CHOHCH2SO3,), named dodecyl sulfobetaine (DSB), was used as a novel modifier to coat dynamically capillary walls for capillary electrophoresis separation of basic proteins. The DSB coating suppressed the electroosmotic flow (EOF) in the pH range of 3,12. At high DSB concentration, the EOF was suppressed by more than 8.8,times. The DSB coating also prevented successfully the adsorption of cationic proteins on the capillary wall. Anions, such as Cl,, Br,, I,, SO42,, CO32,, and ClO4,, could be used as running buffer modifiers to adjust the EOF for better separation of analytes. Using this dynamically coated capillary, a mixture of eight inorganic anions achieved complete separation within 4.2,min with the efficiencies from 24,000 to 1,310,000,plates/m. In the presence of ClO4, as EOF adjustor, the separation of a mixture containing four basic proteins (lysozyme, cytochrome c, ,-chymotrypsinogen,A, and myoglobin) yielded efficiencies of 204,000,896,000,plates/m and recoveries of 88%,98%. Migration time reproducibility of these proteins was less than 0.5% relative standard deviation (RSD) from run to run and less than 3.1% RSD from day to day, showing promising application of this novel modifier in protein separation. [source]


Tracing the route of Sphaerospora truttae from the entry locus to the target organ of the host, Salmo salar L., using an optimized and specific in situ hybridization technique

JOURNAL OF FISH DISEASES, Issue 11-12 2003
A S Holzer
Abstract Sphaerospora truttae is an important pathogen of Atlantic salmon parr in Scottish aquaculture. To trace the early development of S. truttae and to overcome the common problem of detecting low numbers of cryptic, early myxosporean stages, a DNA-based approach was applied in this study. Specific primers were designed for S. truttae from Atlantic salmon, based on 18S rDNA sequences, obtained from isolated myxosporean spores. These were 5, biotin-labelled and used in an optimized and rapid in situ hybridization (ISH) protocol, which provided a strong and specific signal of the parasite within host tissue sections and, at the same time, minimized structural damage to tissues due to processing. This methodology provided a reliable tool enabling the detection of S. truttae stages down to single cell level. Using ISH the epithelium of the gills was identified as the predominant entry locus of the parasite. By 3 days after infection S. truttae had penetrated the vascular epithelia and thereafter proliferated in the blood for at least 10 days before exiting the vascular system through capillary walls. From day 12 post-infection onwards, the kidney, as well as the spleen and the liver, were invaded. Numbers of S. truttae invading the kidney (37.3%) differed little from numbers found in the spleen (35.3%) and the liver (27.4%). The latter organs represented a dead end in the development of S. truttae as all stages in these organs degenerated and sporogony was found to take place exclusively inside the renal tubules. Early sporogonic stages were found from day 25 post-infection but mature spores only developed after at least 15 days of proliferation within the tubules. [source]


The Peritoneal Microcirculation in Peritoneal Dialysis

MICROCIRCULATION, Issue 5 2001
BENGT RIPPE
ABSTRACT This paper deals with the peritoneal microcirculation and with peritoneal exchange occurring in peritoneal dialysis (PD). The capillary wall is a major barrier to solute and water exchange across the peritoneal membrane. There is a bimodal size-selectivity of solute transport between blood and the peritoneal cavity, through pores of radius ,40,50 Å as well as through a very low number of large pores of radius ,250 Å. Furthermore, during glucose-induced osmosis during PD, nearly 40% of the total osmotic water flow occurs through molecular water channels, termed "aquaporin-1." This causes an inequality between 1,, and the sieving coefficient for small solutes, which is a key feature of the "threepore model" of peritoneal transport. The peritoneal interstitium, coupled in series with the capillary walls, markedly modifies small-solute transport and makes large-solute transport asymmetric. Thus, although severely restricted in the blood-to-peritoneal direction, the absorption of large solutes from the peritoneal cavity occurs at a high clearance rate (,1 mL/min), largely independent of molecular radius. True absorption of macromolecules to the blood via lymphatics, however, seems to be occurring at a rate of ,0.2 mL/min. Several controversial issues regarding transcapillary and transperitoneal exchange mechanisms are discussed in this paper. [source]


Role of villus microcirculation in intestinal absorption of glucose: coupling of epithelial with endothelial transport

THE JOURNAL OF PHYSIOLOGY, Issue 2 2003
J. R. Pappenheimer
Capillaries in jejunal villi can absorb nutrients at rates several hundred times greater (per gram tissue) than capillaries in other tissues, including contracting skeletal muscle and brain. We here present an integrative hypothesis to account for these exceptionally large trans-endothelial fluxes and their relation to epithelial transport. Equations are developed for estimating concentration gradients of glucose across villus capillary walls, along paracellular channels and across subjunctional lateral membranes of absorptive cells. High concentrations of glucose discharged across lateral membranes to subjunctional intercellular spaces are delivered to abluminal surfaces of villus capillaries by convection-diffusion in intercellular channels without significant loss of concentration. Post-junctional paracellular transport thus provides the series link between epithelial and endothelial transport and makes possible the large trans-endothelial concentration gradients required for absorption to blood. Our analysis demonstrates that increases of villus capillary blood flow and permeability-surface area product (PS) are essential components of absorptive mechanisms: epithelial transport of normal digestive loads could not be sustained without concomitant increases in capillary blood flow and PS. The low rates of intestinal absorption found in anaesthetised animals may be attributed to inhibition of normal villus microvascular responses to epithelial transport. [source]


Ultrastructural Characterization of Gills in Juveniles of the Argentinian Silverside, Odontesthes bonariensis (Valenciennes, 1835) (Teleostei: Atheriniformes)

ANATOMIA, HISTOLOGIA, EMBRYOLOGIA, Issue 2 2006
F. A. Vigliano
Summary An ultrastructural study was performed on the gills of juvenile Argentinian silverside, Odontesthes bonariensis. The gills are composed of two sets of four holobranchs and, in turn, each holobranch consists of a gill arch and two rows of caudolaterally projecting branchial filaments. From the dorsal and ventral surfaces of each filament, branchial lamellae radiate out as foldings of the epithelial layer. Gill rakers are present on each of the gill arches, on the anteromedial side of the arch opposite to the filaments. Gill rakers, gill arches and branchial filaments are covered by a stratified epithelium, whereas branchial lamellae essentially consist of a thin epithelial envelope containing capillaries. In the stratified epithelium, mucous cells, rodlet cells, granular cells, pavement epithelial cells and mitochondria-rich cells are identified. The thin epithelium that lines the lamellae comprises two cell types, outer and inner epithelial cells, and the capillary walls on the inside of the epithelial envelope are defined by pillar cells. The ultrastructure of all these cell types is described and our findings are discussed in light of the existing data on fish gill morphology. In the gills of juvenile Argentinian silverside is of particular interest the characteristics showed by mitochondria-rich cells, such as their arrangement in clusters of 2,3 cells and their small and depressed surface in contact with the aquatic milieu, features which strongly resemble those of euryhaline species. [source]


Retinal oxygenation in diabetic retinopathy

ACTA OPHTHALMOLOGICA, Issue 2009
SH HARDARSON
Purpose Diabetic retinopathy (DR) is believed to cause retinal tissue hypoxia by damaging retinal capillaries. The purpose of this study was to examine the effect of diabetic retinopathy on oxygen saturation in retinal arterioles and venules. Methods The retinal oximeter (Oxymap ehf., Reykjavik, Iceland) is composed of a fundus camera, beam splitter and light filters. Specialized software calculates relative oxygen saturation from light absorption at two wavelengths of light (605nm and 586nm). One first or second degree temporal arteriole and venule were measured in one eye of 31 healthy individual and 28 patients with diabetic retinopathy. The diabetic patients had background DR (n=6), macular oedema (n=7), untreated preproliferative or proliferative DR (n=7) or stable proliferative DR after treatment (n=8). Statistical analyses were performed with an unpaired t-test, one-way ANOVA and Dunnett's post test. Results Retinal arteriolar saturation was 93±4% (n=31, mean±SD) in healthy subjects and 101±6% (n=28) in patients with DR (p<0.0001). Retinal venular saturation was 58±6% in healthy subjects and 67±8% in diabetic patients (p<0.0001). Arteriolar and venular saturation was higher in all subgroups of diabetic patients (see methods) than in healthy subjects. Conclusion Increased oxygen saturation in retinal vessels in diabetic retinopathy, also found by other researchers, is consistent with poor distribution of blood and oxygen to the retinal tissue rather than decreased total retinal blood flow. Poor distribution of oxygen may be caused by capillary dropouts and shunts as well as thickening of the capillary walls. Commercial interest [source]