CV

Distribution by Scientific Domains
Distribution within Medical Sciences

Terms modified by CV

  • cv death
  • cv disease
  • cv event
  • cv ratio
  • cv risk
  • cv risk factor
  • cv value

  • Selected Abstracts


    Using GIS, Genetic Algorithms, and Visualization in Highway Development

    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, Issue 6 2001
    Manoj K. Jha
    A model for highway development is presented, which uses geographic information systems (GIS), genetic algorithms (GA), and computer visualization (CV). GIS serves as a repository of geographic information and enables spatial manipulations and database management. GAs are used to optimize highway alignments in a complex search space. CV is a technique used to convey the characteristics of alternative solutions, which can be the basis of decisions. The proposed model implements GIS and GA to find an optimized alignment based on the minimization of highway costs. CV is implemented to investigate the effects of intangible parameters, such as unusual land and environmental characteristics not considered in optimization. Constrained optimization using GAs may be performed at subsequent stages if necessary using feedback received from CVs. Implementation of the model in a real highway project from Maryland indicates that integration of GIS, GAs, and CV greatly enhances the highway development process. [source]


    PUBLIC PREFERENCES FOR REHABILITATION VERSUS INCARCERATION OF JUVENILE OFFENDERS: EVIDENCE FROM A CONTINGENT VALUATION SURVEY,

    CRIMINOLOGY AND PUBLIC POLICY, Issue 4 2006
    DANIEL S. NAGIN
    Research Summary: Accurately gauging the public's support for alternative responses to juvenile offending is important, because policy makers often justify expenditures for punitive juvenile justice reforms on the basis of popular demand for tougher policies. In this study, we assess public support for both punitively and nonpunitively oriented juvenile justice policies by measuring respondents' willingness to pay for various policy proposals. We employ a methodology known as "contingent valuation" (CV) that permits the comparison of respondents' willingness to pay (WTP) for competing policy alternatives. Specifically, we compare CV-based estimates for the public's WTP for two distinctively different responses to serious juvenile crime: incarceration and rehabilitation. An additional focus of our analysis is an examination of the public's WTP for an early childhood prevention program. The analysis indicates that the public is at least as willing to pay for rehabilitation as punishment for juvenile offenders and that WTP for early childhood prevention is also substantial. Implications and future research directions are outlined. Policy Implications: The findings suggest that lawmakers should more actively consider policies grounded in rehabilitation, and, perhaps, be slower to advocate for punitive reforms in response to public concern over high-profile juvenile crimes. Additionally, our willingness to pay findings offer encouragement to lawmakers who are uncomfortable with the recent trend toward punitive juvenile justice policies and would like to initiate more moderate reforms. Such lawmakers may be reassured that the public response to such initiatives will not be hostile. Just as importantly, reforms that emphasize leniency and rehabilitation can be justified economically as welfare-enhancing expenditures of public funds. The evidence that the public values rehabilitation more than increased incarceration should be important information to cost-conscious legislators considering how to allocate public funds. Cost-conscious legislatures may become disenchanted with punitive juvenile justice policies on economic grounds and pursue policies that place greater emphasis on rehabilitation. They may be reassured, on the basis of our findings, that the public will support this move. [source]


    Quality control of CD4+ T-lymphocyte enumeration: Results from the last 9 years of the United Kingdom national external quality assessment scheme for immune monitoring (1993,2001)

    CYTOMETRY, Issue 2 2002
    Liam Whitby
    Abstract The human immunodeficiency virus (HIV) global epidemic has necessitated the routine enumeration of T-lymphocyte subsets, which has created a need for external quality assurance (EQA). The United Kingdom National External Quality Assessment Scheme (UK NEQAS) for Immune Monitoring provides EQA for 296 laboratories in 40 countries. In 1993, UK NEQAS developed and incorporated into its program stabilized whole blood that enables the accurate monitoring of laboratory performance. Overall, the mean interlaboratory coefficient of variation (CV) for percentage CD4+ T-lymphocyte subset enumeration has fallen from 15% to less than 5%, as a direct result of the increased use of CD45/ side scatter (SSC) gating. Laboratories using alternative gating strategies (i.e., CD45/CD14 or forward scatter [FSC]/SSC) were about 7.4 times more likely to fail an EQA exercise. Furthermore, the adoption of single-platform technology resulted in a reduction of the overall mean interlaboratory CV for absolute CD4+ T lymphocytes from 56% (prior to the widespread use of single-platform technology) to 9.7%. Individual laboratory deficiencies were also identified using a performance monitoring system and, through re-education by collaboration with the coordinating center, satisfactorily resolved. In conclusion, during the last 9 years, the UK NEQAS for Immune Monitoring program has highlighted the significant technological advances made by laboratories worldwide that undertake lymphocyte subset enumeration. Cytometry (Clin. Cytometry) 50:102,110, 2002. © 2002 Wiley-Liss, Inc. [source]


    A cardiologist view of vascular disease in diabetes

    DIABETES OBESITY & METABOLISM, Issue 4 2008
    Christopher J. Lockhart
    Diabetes mellitus is a potent risk factor for the development of a wide spectrum of cardiovascular (CV) complications. The complex metabolic milieu accompanying diabetes alters blood rheology, the structure of arteries and disrupts the homeostatic functions of the endothelium. These changes act as the substrate for end-organ damage and the occurrence of CV events. In those who develop acute coronary syndromes, patients with diabetes are more likely to die, both in the acute phase and during follow-up. Patients with diabetes are also more likely to suffer from chronic cardiac failure, independently of the presence of large vessel disease, and also more likely to develop stroke, renal failure and peripheral vascular disease. Preventing vascular events is the primary goal of therapy. Optimal cardiac care for the patient with diabetes should focus on aggressive management of traditional CV risk factors to optimize blood glucose, lipid and blood pressure control. Targeting medical therapy to improve plaque stability and diminish platelet hyper-responsiveness reduces the frequency of events associated with atherosclerotic plaque burden. In patients with critical lesions, revascularization strategies, either percutaneous or surgical, will often be necessary to improve symptoms and prevent vascular events. Improved understanding of the vascular biology will be crucial for the development of new therapeutic agents to prevent CV events and improve outcomes in patients with diabetes. [source]


    Attenuating CV risk factors in patients with diabetes: clinical evidence to clinical practice

    DIABETES OBESITY & METABOLISM, Issue 2002
    Alan J. Garber
    Abstract Individuals with diabetes are at high risk of cardiovascular (CV) disease, a risk that is significantly greater in the presence of traditional CV risk factors (hyperlipidaemia, hypertension, prothrombotic state). Glucose control and management of these risk factors decreases but does not eliminate CV events, reflecting the complexity of atherosclerosis. Novel risk factors (C-reactive protein, lipoprotein a, homocysteine, and endothelial dysfunction) have been proposed and are potentially modifiable. However, clinical trials data are not yet available to guide therapy. At this time, no single agent can achieve adequate risk reduction in patients with diabetes. Even with the use of multiple agents and classes of agents to manage CV risk, 75% of patients with diabetes are expected to die from CV causes. Despite the recent advances in primary and secondary prevention of CV events, new approaches are needed. Data from the Heart Outcomes Prevention Evaluation (HOPE) trial demonstrated that CV risk can be further reduced by the addition of the ACE inhibitor ramipril to the existing treatment regimen of high-risk patients with diabetes. [source]


    Leptin,a predictor of abnormal glucose tolerance and prognosis in patients with myocardial infarction and without previously known Type 2 diabetes

    DIABETIC MEDICINE, Issue 8 2008
    M. Wallander
    Abstract Aims High levels of leptin and low adiponectin are associated with Type 2 diabetes mellitus (T2DM) and cardiovascular (CV) disease. We studied the prognostic implications of leptin and adiponectin in patients with acute myocardial infarction (AMI) without previously known Type 2 DM. Methods One hundred and eighty-one patients were included. Based on an oral glucose tolerance test at hospital discharge (day 4,5), 168 (67% men) had normal or abnormal glucose tolerance (AGT), defined as impaired glucose tolerance or T2DM. Sex- and age-matched healthy persons served as control subjects (n = 185). The associations between fasting serum leptin and adiponectin (day 2) and newly discovered AGT and CV events (CV mortality, non-fatal stroke, reinfarction or severe heart failure) during a median follow-up of 34 months were investigated. Results Compared with control subjects, patients of both genders had significantly higher levels of leptin 2 days after an AMI. These levels were higher than those obtained at hospital discharge and 3 months later. Circulating levels of (ln) leptin 2 days after the AMI predicted AGT at discharge (odds ratio 2.03, P = 0.042). Ln leptin at day 2 was the only biochemical variable that significantly predicted CV events both on univariate [hazard ratio (HR) 1.60, P = 0.018] and on multivariate analysis (HR 1.75, P = 0.045). Adiponectin levels did not differ between patients and control subjects and did not relate to AGT or CV events. Conclusions Elevated circulating levels of leptin on the first morning after an AMI are associated with the presence of AGT at discharge and with a poorer long-term prognosis. [source]


    The MTHFR C677T polymorphism confers a high risk for stroke in both homozygous and heterozygous T allele carriers with Type 2 diabetes

    DIABETIC MEDICINE, Issue 5 2006
    M. P. Hermans
    Abstract Objective Individuals with Type 2 diabetes are at increased risk of stroke. Plasma homocysteine (tHcy) is an independent risk factor for cardiovascular (CV) disease. The methylene,tetrahydrofolate reductase (MTHFR) gene polymorphism (thermolabile variant C677T) is associated with CV risk, partly as a result of increased Hcy, especially in homozygous subjects. Aim To relate the occurrence of the MTHFR polymorphism with stroke prevalence by examining allelic frequency and genotype distribution in 165 subjects with Type 2 diabetes studied for the presence of thermolabile C677T MTHFR mutation. Results Mean age was 67.7 years, and tHcy 18.2 µmol/l. T allele frequency was 38.5%. MTHFR genotypes were: normal (CC) 40%; heterozygous (CT) 43%; homozygous (TT) 17%. Serum levels of folic acid and B12 vitamin were within normal limits. Stroke prevalence was 14%. Sixty-four per cent of stroke-free subjects had the normal C allele vs. 46% in stroke subjects. The frequencies of genotypes (CC-CT-TT) were (%): 44-41-15 in stroke-free vs. 17-57-26 in stroke patients. Coronary (CAD) and peripheral artery disease (PAD) were common in all groups, with no differences according to genotypes. Stroke prevalence was markedly higher in genotypes CT and TT (18 and 21%) compared with CC (6%). Mean tHcy levels were higher in TT subjects. Conclusion The allelic frequency of C677T MTHFR mutation in Type 2 diabetes subjects with stroke is markedly different from that of subjects without stroke. Genotypic characteristics suggest that C677T MTHFR mutation confers a higher risk for stroke to both homozygous and heterozygous T allele carriers that cannot be ascribed solely to raised tHcy and/or lower folate status in CT subjects, nor to phenotypic expression of conventional risk factors for stroke. The impact of the MTHFR polymorphism on stroke may result from T allele-linked deleterious effects, or C allele-linked protection. Confirmatory studies are warranted, as this cohort was not randomly selected, and a type 1 error cannot be ruled out. [source]


    Dichotic listening deficits in children with dyslexia

    DYSLEXIA, Issue 1 2008
    Deborah W. Moncrieff
    Abstract Several auditory processing deficits have been reported in children with dyslexia. In order to assess for the presence of a binaural integration type of auditory processing deficit, dichotic listening tests with digits, words and consonant,vowel (CV) pairs were administered to two groups of right-handed 11-year-old children, one group diagnosed with developmental dyslexia and an age-matched control group. Dyslexic children performed more poorly than controls from their left ears when listening to digits and words and from their right ears when listening to CVs. Direction of ear advantage varied across individuals in both groups when tested with digits and CVs, but ear advantage was stable with words. Several factors that may have contributed to inconsistencies in direction of ear advantage are discussed. When the children were tested in a directed response mode, degree of ear advantage differed significantly between groups with both words and digits. More dyslexic than control children demonstrated clinically significant reductions in dichotic listening performance, but no uniform pattern of deficit emerged. Only the double correct score and the left ear score with CV pairs were predictive of word recognition performance in dyslexic children. Binaural integration deficits are present in some children with dyslexia. Auditory processing disorder assessment may help delineate factors that underlie or are associated with reading impairment in this population. Copyright © 2007 John Wiley & Sons, Ltd. [source]


    A yield displacement distribution-based approach for strength assignment to lateral force-resisting elements having strength dependent stiffness

    EARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS, Issue 15 2003
    W. K. Tso
    Abstract Recent studies have shown that for many lateral force-resisting elements (LFRE) stiffness is dependent on strength, and as a result strength assignment to these elements would affect both the strength and stiffness distributions in a structure. Consequently, stiffness distribution cannot be considered known prior to strength assignment. This paper presents a yield displacement distribution-based strength assignment strategy that does not require the knowledge of stiffness distribution prior to strength assignment. It is shown that structural systems with their center of rigidity (CR) and center of strength (CV) located on the opposite sides of the center of mass (CM) will have small torsional responses under seismic excitation. Copyright © 2003 John Wiley Sons, Ltd. [source]


    Ten-Year Echo/Doppler Determination of the Benefits of Aerobic Exercise after the Age of 65 Years

    ECHOCARDIOGRAPHY, Issue 1 2010
    Alexander J. Muster M.D.
    As the human lifespan becomes progressively extended, potential health-related effects of intense aerobic exercise after age 65 need evaluation. This study evaluates the cardiovascular (CV), pulmonary, and metabolic effects of competitive distance running on age-related deterioration in men between 69 (±3) and 77 (±2) years (mean ± SD). Twelve elderly competitive distance runners (ER) underwent oxygen consumption and echo/Doppler treadmill stress testing (Balke protocol) for up to 10 years. Twelve age-matched sedentary controls (SC) with no history of CV disease were similarly tested and the results compared for the initial three series of the study. CV data clearly separated the ER from SC. At entry, resting and maximal heart rate, systolic/diastolic blood pressure, peak oxygen consumption (VO2max), and E/A ratio of mitral inflow were better in the ER (P < 0.05 vs. SC). With aging, ER had a less deterioration of multiple health parameters. Exceptions were VO2max and left ventricular diastolic function (E/A, AFF, IVRT) that decreased (P < 0.05, Year 10 vs. Year 1). Health advantages of high-level aerobic exercise were demonstrated in the ER when compared to SC. Importantly, data collected in ER over 10 years confirm the benefit of intensive exercise for slowing several negative effects of aging. However, the normative drop of exercise capacity in the seventh and eighth decades reduces the potential athleticism plays in prevention of CV events. (Echocardiography 2010;27:5-10) [source]


    Predictors for Maintenance of Sinus Rhythm after Cardioversion in Patients with Nonvalvular Atrial Fibrillation

    ECHOCARDIOGRAPHY, Issue 5 2002
    Ökçün M.D.
    Recurrence of atrial fibrillation (AF) after cardioversion (CV) to sinus rhythm (SR) is determined by various clinical and echocardiographic parameters. Transesophageal echocardiographic (TEE) parameters have been the focus of clinicians' interests for restoring and maintaining SR. This study determined the clinical, transthoracic, and TEE parameters that predict maintenance of SR in patients with nonvalvular AF after CV. We enrolled 173 patients with nonvalvular AF in the study. TEE could not be performed in 26 patients prior to CV. Twenty-five patients had spontaneously CV prior to TEE. Six patients were excluded because of left atrial (LA) thrombus assessed by TEE. CV was unsuccessful in 6 patients. The remaining 110 consecutive patients (56 men, 54 women, mean age 69 ± 9 years), who had been successfully cardioverted to SR, were prospectively included in the study. Fifty-seven (52%) patients were still in SR 6 months after CV. Age, gender, the configuration of the fibrillation wave on the electrocardiogram, pulmonary venous diastolic flow, and the presence of diabetes, hypertension, coronary artery disease, mitral annulus calcification, and mitral valve prolapse (MVP) did not predict recurrence. Duration of AF, presence of chronic obstructive pulmonary disease (COPD), LA diameter, left ventricular ejection fraction (EF), left atrial appendage peak flow (LAAPF), LAA ejection fraction (LAAEF), pulmonary venous systolic flow (PVSF), and the presence of LA spontaneous echo contrast (LASEC) predicted recurrence of AF 6 months after CV. In multivariate analysis, LAAEF < 30% was found to be the only independent variable (P < 0.0012) predicting recurrence at 6 months after CV in patients with nonvalvular AF. LAAEF more than 30% had a sensitivity of 75% and a specificity of 88% in predicting maintenance of SR 6 months after CV in patients with nonvalvular AF. In conclusion, TEE variables often used to determine thromboembolic risk also might be used to predict the outcome of CV. [source]


    Precipitation control over inorganic nitrogen import,export budgets across watersheds: a synthesis of long-term ecological research

    ECOHYDROLOGY, Issue 2 2008
    E. S. Kane
    Abstract We investigated long-term and seasonal patterns of N imports and exports, as well as patterns following climate perturbations, across biomes using data from 15 watersheds from nine Long-Term Ecological Research (LTER) sites in North America. Mean dissolved inorganic nitrogen (DIN) import,export budgets (N import via precipitation,N export via stream flow) for common years across all watersheds was highly variable, ranging from a net loss of , 0·17 ± 0·09 kg N ha,1mo,1 to net retention of 0·68 ± 0·08 kg N ha,1mo,1. The net retention of DIN decreased (smaller import,export budget) with increasing precipitation, as well as with increasing variation in precipitation during the winter, spring, and fall. Averaged across all seasons, net DIN retention decreased as the coefficient of variation (CV) in precipitation increased across all sites (r2 = 0·48, p = 0·005). This trend was made stronger when the disturbed watersheds were withheld from the analysis (r2 = 0·80, p < 0·001, n = 11). Thus, DIN exports were either similar to or exceeded imports in the tropical, boreal, and wet coniferous watersheds, whereas imports exceeded exports in temperate deciduous watersheds. In general, forest harvesting, hurricanes, or floods corresponded with periods of increased DIN exports relative to imports. Periods when water throughput within a watershed was likely to be lower (i.e. low snow pack or El Niño years) corresponded with decreased DIN exports relative to imports. These data provide a basis for ranking diverse sites in terms of their ability to retain DIN in the context of changing precipitation regimes likely to occur in the future. Copyright © 2008 John Wiley & Sons, Ltd. [source]


    Identification of Standard Auction Models

    ECONOMETRICA, Issue 6 2002
    Susan Athey
    This paper presents new identification results for models of first,price, second,price, ascending (English), and descending (Dutch) auctions. We consider a general specification of the latent demand and information structure, nesting both private values and common values models, and allowing correlated types as well as ex ante asymmetry. We address identification of a series of nested models and derive testable restrictions enabling discrimination between models on the basis of observed data. The simplest model,symmetric independent private values,is nonparametrically identified even if only the transaction price from each auction is observed. For richer models, identification and testable restrictions may be obtained when additional information of one or more of the following types is available: (i) the identity of the winning bidder or other bidders; (ii) one or more bids in addition to the transaction price; (iii) exogenous variation in the number of bidders; (iv) bidder,specific covariates. While many private values (PV) models are nonparametrically identified and testable with commonly available data, identification of common values (CV) models requires stringent assumptions. Nonetheless, the PV model can be tested against the CV alternative, even when neither model is identified. [source]


    A New Amperometric Hydrazine Sensor Based on Prussian Blue/Single-walled Carbon Nanotube Nanocomposites

    ELECTROANALYSIS, Issue 16 2010
    Cong Wang
    Abstract A slow reaction process has been successfully used to synthesize Prussian blue/single-walled carbon nanotubes (PB/SWNTs) nanocomposites. Electrochemical and surface characterization by cyclic voltammetry (CV), scanning electron microscopy (SEM), transmission electron microscopy (TEM), UV-vis absorption spectroscopy, Fourier transform infrared (FTIR) spectroscopy and X-ray diffraction (XRD) confirmed the presence of PB nanocrystallites on SWNTs. PB/SWNTs modified glassy carbon electrode (GCE) exhibits efficient electron transfer ability and high electrochemical response towards hydrazine. The fabricated hydrazine sensor showed a wide linear range of 2.0×10,6,6.0×10,3,M with a response time less than 4,s and a detection limit of 0.5,,M. PB/SWNTs modified electrochemical sensors are promising candidates for cost-effective in the hydrazine assays. [source]


    A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotube/Chitosan Composite as a New Sensor for Simultaneous Determination of Acetaminophen and Mefenamic Acid in Pharmaceutical Preparations and Biological Samples

    ELECTROANALYSIS, Issue 15 2010
    Ali Babaei
    Abstract A new chemically modified electrode is constructed based on multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs-CHT/GCE) for simultaneous determination of acetaminophen (ACT) and mefenamic acid (MEF) in aqueous buffered media. The measurements were carried out by application of differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA) methods. Application of DPV method showed that the linear relationship between oxidation peak current and concentration of ACT and MEF were 1,,M to 145,,M, and 4,,M to 200,,M, respectively. The analytical performance of this sensor has been evaluated for detection of ACT and MEF in human serum, human urine and a pharmaceutical preparation with satisfactory results. [source]


    A Novel Polycatechol/Ordered Mesoporous Carbon Composite Film Modified Electrode and Its Electrocatalytic Application

    ELECTROANALYSIS, Issue 15 2010
    Jing Bai
    Abstract Polycatechol (PCC) was prepared by electropolymerizing catechol (CC) on the surface of an ordered mesoporous carbon (OMC) modified electrode for the first time. Scanning electron microscopy (SEM) and cyclic voltammetry (CV) were used to characterize the structure and electrochemical behaviors of PCC/OMC nanocomposite film. Compared with the bare GC and OMC/GC electrodes, the PCC/OMC/GC electrode exhibits a good electrocatalysis toward the oxidation of NADH at 0.0,V with a high sensitivity (8.7 mA/mM). These make PCC/OMC/GC electrode a promising candidate for stable and efficient electrochemical sensors for the detection of NADH. [source]


    Green Synthesis of Silver Nanoparticles Using Ionic Liquid and Application for the Detection of Dissolved Oxygen

    ELECTROANALYSIS, Issue 6 2010
    Tsung-Hsuan Tsai
    Abstract The electrochemical synthesis of silver nanoparticles (nano-Ag) has been successfully carried out on glassy carbon electrode (GCE) and indium tin oxide electrode (ITO) using 1-butyl-3-methylimidazolium tetrafluoroborate (BMT) as green electrolytes. Further the electrodeposited nano-Ag modified ITO electrode has been examined using atomic force microscopy (AFM), and X-ray diffraction studies (XRD). The electrodeposited Ag nanoparticles on ITO were found in the size range of 5 to 35,nm. The nano-Ag film modified GCE was further coated with nafion (Nf) and BMT (1,:,1 ratio) mixture and found to be stable in BMT and in pH,7 phosphate buffer solution (PBS). The nano-Ag/BMT-Nf film modified GCE successfully applied for the oxygen reduction reaction in neutral pH (pH,7.0 PBS). The proposed film modified GCE successfully reduces the over potential and show well defined reduction peaks for the detection of dissolved oxygen using cyclic voltammetry (CV) and rotating disc voltammetry (RDE). The film also applied for the detection of dissolved oxygen using electrochemical impedance spectroscopic studies (EIS). [source]


    Mediated Electron Transfer Across Supported Bilayer Lipid Membrane with TCNQ-Based Organometallic Compounds

    ELECTROANALYSIS, Issue 4 2010
    Meili Qu
    Abstract Supported bilayer lipid membrane (s-BLM) containing one-dimensional compound 1, TCNQ-based (TCNQ=7,7,8,8-tetracyanoquinodimethane) organometallic compound {(Cu2(,-Cl)(,-dppm)2)(,2 -TCNQ)},, was prepared and characterized on the self-assembled monolayer (SAM) of 1-octadecylmercaptan (C18H37SH) deposited onto Au electrode. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) results showed that the compound 1, dotted inside s-BLM, can act as mediator for electron transfer across the membrane. Two redox peaks and the charge-transfer resistance of 400,k, were observed for compound 1 inside s-BLM. The mechanism of the electron transfer across s-BLM by TCNQ is by electron hopping while TCNQ-based organometallic compound is by conducting. Further conclusion drawn from this finding is that the TCNQ-based organometallic compound embedded inside s-BLM exhibits excellent electron transfer ability than that of free TCNQ. This opens a new path for the development of s-BLM sensor and/or biosensor by incorporation with TCNQ-based organometallic compounds. [source]


    Electrocatalytic Oxidation of Glucose by the Glucose Oxidase Immobilized in Graphene-Au-Nafion Biocomposite

    ELECTROANALYSIS, Issue 3 2010
    Kangfu Zhou
    Abstract Graphene was successfully prepared and well separated to individual sheets by introducing SO3,. XRD and TEM were employed to characterize the graphene. UV-visible absorption spectra indicated that glucose oxidase (GOx) could keep bioactivity well in the graphene-Au biocomposite. To construct a novel glucose biosensor, graphene, Au and GOx were co-immobilized in Nafion to further modify a glassy carbon electrode (GCE). Electrochemical measurements were carried out to investigate the catalytic performance of the proposed biosensor. Cyclic voltammograms (CV) showed the biosensor had a typical catalytic oxidation response to glucose. At the applied potential +0.4,V, the biosensor responded rapidly upon the addition of glucose and reached the steady state current in 5,s, with the present of hydroquinone. The linear range is from 15,,M to 5.8,mM, with a detection limit 5,,M (based on the S/N=3). The Michaelis-Menten constant was calculated to be 4.4,mM according to Lineweaver,Burk equation. In addition, the biosensor exhibits good reproducibility and long-term stability. Such impressive properties could be ascribed to the synergistic effect of graphene-Au integration and good biocompatibility of the hybrid material. [source]


    Peculiarities of Electrochemical Bismuth Film Formation in the Presence of Bromide and Heavy Metal Ions

    ELECTROANALYSIS, Issue 15 2009
    Giedr, Grincien
    Abstract Bi films were deposited on glassy carbon electrode from solutions with and without KBr. The morphology of both types of the films was characterized by scanning electron microscopy (SEM), and their electrochemical behavior was studied by square wave (SWV) and cyclic voltammetry (CV). Bi films were also co-deposited with common analyte-heavy-metals in the presence of KBr and these films also were characterized by SEM, SWV and CV in order to understand the formation of the mixed metal films. All films studied had a different morphology. Bromide addition made the Bi films more compact and uniform, whereas Pb catalyzed Bi film deposition. [source]


    The Preliminary Studies of Electrochemical Behavior of Paracetamol and Its Metabolites on Glassy Carbon Electrode by Voltammetric Methods

    ELECTROANALYSIS, Issue 10 2009
    Irena Baranowska
    Abstract The new, rapid and sensitive method for the determination of paracetamol (PAR) and its glucuronide (PG) and sulfate (PS) metabolites is proposed. The electrochemical properties of the compounds were examined by cyclic voltammetry (CV) on glassy carbon electrode (GCE). All measurements were carried out in Britton,Robinson buffers (BR) with different pH values over the pH range 1.81,7.24. The preliminary research indicated that PAR could be determined simultaneously with one of its metabolites. The linearity of calibration curves was obtained for concentrations between 1.65×10,5 and 1.65×10,4 M for PAR, 1.53×10,5 and 1.53×10,4 M for PG and 2.17×10,5 and 1.52×10,4 M for PS. [source]


    Simultaneous Determination of Dopamine and Ascorbic Acid Using the Nano-Gold Self-Assembled Glassy Carbon Electrode

    ELECTROANALYSIS, Issue 10 2009
    Guangzhi Hu
    Abstract Electrochemical behavior of dopamine (DA) was investigated at the gold nanoparticles self-assembled glassy carbon electrode (GNP/LC/GCE), which was fabricated by self-assembling gold nanoparticles on the surface of L -cysteine (LC) modified glassy carbon electrode (GCE) via successive cyclic voltammetry (CV). A pair of well-defined redox peaks of DA on the GNP/LC/GCE was obtained at Epa=0.197,V and Epc=0.146,V, respectively. And the peak separation between DA and AA is about 0.2,V, which is enough for simultaneous determination of DA and AA. The peak currents of DA and AA were proportional with their concentrations in the range of 6.0×10,8,8.5×10,5 mol L,1 and 1.0×10,6,2.5×10,3 mol L,1, with the detection limit of 2.0×10,8 mol L,1 and 3.0×10,7 mol L,1 (S/N=3), respectively. The modified electrode exhibits an excellent reproducibility, sensibility and stability for simultaneous determination of DA and AA in human serum with satisfactory result. [source]


    Preparation and Characterization of a Tin Pentacyanonitrosylferrate-Modified Carbon Ceramic Electrode: Application to Electrocatalytic Oxidation and Amperometric Detection of L -Cysteine

    ELECTROANALYSIS, Issue 7 2009
    H. Razmi
    Abstract The sol-gel technique was used to construct tin pentacyanonitrosylferrate (SnPCNF) modified composite carbon ceramic electrode (CCE). This involves two steps: construction of CCE containing metallic Sn powder and then electrochemical creating of SnPCNF on the surface of CCE. The SnPCNF modified CCE (SnPCNFlCCE) was characterized by energy-dispersive X-ray (EDX), FTIR and cyclic voltammetry (CV) techniques. The SnPCNF film showed electrocatalytic activity toward the oxidation of L -cysteine. A linear calibration plot was obtained over the L -cysteine concentration range 1,51,,M using chronoamperometry. L -cysteine was determined amperometrically at the surface of this modified electrode. The detection limit (for a signal to noise of 3) and sensitivity were found to be 0.62,,M and 126,,A/mM, respectively. [source]


    Direct Electrochemistry and Electrocatalysis of Hemoglobin in Lipid Film Incorporated with Room-Temperature Ionic Liquid

    ELECTROANALYSIS, Issue 20 2008
    Gaiping Li
    Abstract A facile phospholipid/room-temperature ionic liquid (RTIL) composite material based on dimyristoylphosphatidylcholine (DMPC) and 1-butyl-3-methylimidazolium hexafluorophosphate ([bmim]PF6) was exploited as a new matrix for immobilizing protein. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were adopted to characterize this composite film. Hemoglobin (Hb) was chosen as a model protein to investigate the composite system. UV-vis absorbance spectra showed that Hb still maintained its heme crevice integrity in this composite film. By virtue of the Hb/DMPC/[bmim]PF6 composite film-modified glassy carbon electrode (GCE), a pair of well-defined redox peaks of Hb was obtained through the direct electron transfer between protein and underlying GCE. Moreover, the reduction of O2 and H2O2 at the Hb/DMPC/[bmim]PF6 composite film-modified GCE was dramatically enhanced. [source]


    Some Properties of Sodium Dodecyl Sulfate Functionalized Multiwalled Carbon Nanotubes Electrode and Its Application on Detection of Dopamine in the Presence of Ascorbic Acid

    ELECTROANALYSIS, Issue 16 2008
    Dan Zheng
    Abstract A sodium dodecyl sulfate (SDS) functionalized multiwalled carbon nanotubes (MWNTs) electrode (SDS/MWNTs) was successfully constructed in this study. The electrochemical property of the SDS/MWNTs electrode has been characterized by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Nyquist plots suggest that the immersion time of SDS affects the resistances of the MWNTs electrodes. The thickness of adsorbed SDS on MWNTs surface is estimated to be 1.23,nm, which is close to the value of SDS monolayer. CV results demonstrate a 5-fold enhanced response for dopamine (DA) at the SDS/MWNTs electrode compared to the bare MWNTs one. DPV results illustrate that DA can be selectively determined in the presence of high concentration ascorbic acid (AA) with a linear range from 20,,M to 0.20,mM and a sensitivity of 0.024,,A ,M,1 at the SDS/MWNTs electrode. [source]


    Voltammetric Reduction of a 4-Nitroimidazole Derivative on a Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrode

    ELECTROANALYSIS, Issue 13 2008
    P. Jara-Ulloa
    Abstract We report the electrochemical behavior of a 4-nitroimidazole derivative, 1-methyl-4-nitro-2-hydroxymethylimidazole (4-NImMeOH), on glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT). As dispersing agents, dimethylformamide (DMF) and water were used. The electrochemical response of the resulting electrodes was evaluated using linear sweep, cyclic and square-wave voltammetry (LSV, CV and SWV). Several parameters such as medium pH, nature and concentration of the CNTs dispersion and accumulation time were tested. The optimal conditions determined for obtain better response were: pH,2, dispersion concentration=4,mg/mL of CNT in water, accumulation time=7,min. The MWCNT-modified GCE exhibited attractive electrochemical properties producing enhanced currents with a significant reduction in the overpotential and good signal-to-noise characteristics, in comparison with the bare GCE. The modified electrode is highly repeatable for consecutive measurements, reaching a variation coefficient of 2.9% for ten consecutive runs. [source]


    Selective Determination of Dopamine in the Presence of Ascorbic Acid at Porous-Carbon-Modified Glassy Carbon Electrodes

    ELECTROANALYSIS, Issue 11 2008
    Shuqing Song
    Abstract Selective dopamine (DA) determinations using porous-carbon-modified glassy carbon electrodes (GCE) in the presence of ascorbic acid (AA) were studied. The effects of structure textures and surface functional groups of the porous carbons on the electrochemical behavior of DA was analyzed based on both cyclic voltammetry (CV) and differential pulse voltammetry (DPV) measurements. The differential pulse voltammetry of DA on the modified GCE was determined in the presence of 400-fold excess of AA, and the linear determination ranges of 0.05,0.99, 0.20,1.96, and 0.6,12.60,,M with the lowest detected concentrations of 4.5×10,3, 4.4×10,2, and 0.33,,M were obtained on the mesoporous carbon, mesoporous carbon with carboxylic and amino groups modified electrodes, respectively. [source]


    Fabrication and Application of a Novel Modified Electrode Based on Multiwalled Nanotubes/Cerium(III) 12-Tungstophosphoric Acid Nanocomposite

    ELECTROANALYSIS, Issue 11 2008
    Bin Fang
    Abstract A novel multiwalled nanotubes (MWNTs)/Cerium(III) 12 - tungstophosphoric acid (CePW) nanocomposite film glassy carbon electrode was prepared in this paper. Electrochemical behaviors of the CePW/MWNTs modified electrode were investigated by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). This modified electrode brought new capabilities for electrochemical devices by combining the advantages of carbon nanotubes, rare-earth, and heteropoly-acids. The results demonstrated that the CePW/MWNTs modified electrode exhibited enhanced electrocatalytic behavior and good stability for the detection of guanine and adenine in 0.1,M PBS (pH,7.0). The experimental parameters were optimized and a direct electrochemical method for the simultaneous determination of guanine and adenine was proposed. The detection limit (S/N=3) for guanine and adenine was 2.0×10,8,M and 3.0×10,8,M, respectively. Further, the acid-denatured calf thymus DNA was also detected and the result was satisfied. [source]


    Differential Pulse Voltammetric Determination of Uric Acid on Carbon-Coated Iron Nanoparticle Modified Glassy Carbon Electrodes

    ELECTROANALYSIS, Issue 10 2008
    Shengfu Wang
    Abstract A carbon-coated iron nanoparticles (CIN, a new style fullerence related nanomaterial) modified glassy carbon electrode (CIN/GCE) has been developed for the determination of uric acid (UA). Electrochemical behaviors of UA on CIN/GCE were explored by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that the voltammetric response of UA on CIN/GC was enhanced dramatically because of the strong accumulation effect of CIN and the large working area of the CIN/GC electrode. The parameters including the pH of supporting electrolyte, accumulation potential and time, that govern the analytical performance of UA have been studied and optimized. The DPV signal of UA on CIN/GCE increased linearly with its concentration in the range from 5.0×10,7 to 2.0×10,5 M, with a detection limit of 1.5×10,7 M (S/N=3). The CIN/GCE was used for the determination of UA in samples with satisfactory results. The proposed CIN/GCE electrochemical sensing platform holds great promise for simple, rapid, and accurate detection of UA. [source]


    Preparation of Novel Arrays Silver Nanoparticles Modified Polyrutin Coat-Paraffin-Impregnated Graphite Electrode for Tyrosine and Tryptophan's Oxidation

    ELECTROANALYSIS, Issue 8 2008
    Guan-Ping Jin
    Abstract A novel array silver nanoparticles and Rutin complex film modified paraffin-impregnated graphite electrode was proposed in this work (denoted as Ag/Rutin/WGE). The characteristics were investigated by the field emission scanning electron microscopy (FE-SEM), infrared spectra (IR), UV-visible (UV), X-ray photoelectron spectroscopy (XPS) and electrochemical techniques. Silver ions were gradually chelated by polyrutin film at 4,-oxo-5,-OH and 5-OH-4-oxo sites accompanying adsorption, then. Silver nanoparticles were highly-dispersed electrodeposited on polyrutin film. The electrochemical behaviors of tyrosine (Tyr) and tryptophan (Trp) were studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The Ag/Rutin/WGE electrode shows overlapping catalysis for the oxidation of Tyr and Trp. The linear response of Tyr and Trp were 0.3,10.0 and 0.7,70.0,,M with detection limit of 0.07 and 0.1,,M in a signal-to-noise ratio of 3. [source]